Cut Sheet
D-22
WWW.IDEALINDUSTRIES.COM 1-800-435-0705 CUSTOMER ASSISTANCE
TesT & MeasureMenT
replaCeMenT parTs/safeTy
Replacement Parts Selection Guide
Safety in the Field
Thepowerdemandsoftoday’shigh-techworldhavecausedamarkedincreasein
occurrencesandlevelsoftransientovervoltages.TheInternationalElectrotechnical
Commission(IEC)hasdevelopedasafetystandardsmodelformeasurement,controland
laboratoryuse.
Category I–Thesignallevelfortelecommunications,electronicandotherlow-energy
equipmentwithtransient-limitingprotection.Peakimpulsetransientrangeis600–4,000volts
witha30ohmsource.
Category II –Thelocallevelforfixedandnon-fixedpowereddevicesincludingappliances,
lightingandportableequipment.Outletslocatedmorethan30feetfromCATIIIsourcesand
60feetfromCATIVsources.Peakimpulsetransientrangeisfrom600–6,000voltswitha12
ohmsource.
Category III –Thedistributionlevelforfixedprimaryfeedersorbranchcircuits.Circuits
thatareseparatedfromCATIVsourcesbyatleastoneleveloftransformerisolation.Peak
impulsetransientrangeis600–8,000voltswitha2ohmsource.
Category IV (proposed)–Theprimarysupplylevelforthehighestlevelsoftransient
overvoltage.Includestheutilityservicebothoutsideandattheserviceentrance,servicedrop
fromthepoletothebuilding,overheadlinetoremotebuildings,andundergroundlinetoa
wellpump.Peakimpulsetransientrangeis600–12,000voltswithlessthana1ohmsource.
CAT I
Copiers
• Electronic
equipment
• Low energy
equipment with
transient limiting
protection
CAT II
Appliances,
PCs, TVs
• Outlets and long
branch equipment
• All outlets at more
than 10m (30 ft)
from Category III
source
• All outlets at more
than 20m (60 ft)
from Category IV
source
CAT III
MC Panels
• Feeders and short
branch circuits
• Distribution
panel devices
• Heavy appliance
outlets with “short”
connections to
service entrance
CAT IV
Exterior
Tr ansformers,
Meters
• Outside and
service entrance
• Service drop from
pole to building
• Overhead line to
detached building
• Underground line
to well pump
Service
Entrance
Service
Entrance
Meter
Meter
Meter
Transformer
Outbuilding
Underground Service
Service
Entrance
Outbuilding
Underground Service
METER REPACEMENT PARTS
SELECTION GUIDE
090 310 340 360 480 490 600 610 700 740 760 770 790
61-096
61-310
61-312
61-340
61-342
61-361
61-484
61-486
61-497
61-498
61-605
61-610
61-614
61-702
61-704
61-744
61-746
61-763
61-765
61-773
61-775
61-795
61-797
FUSES
F-1 0.5A (250V) 6.35 x 38mm •
F-105 1A (600V) 10.3 x 35mm •
F-310 250mA (250V) 5 x 20mm • •
F-312 500mA (250V) 5 x 20mm •
F-314 10A (250V) 5 x 20mm •
F-340 0.5A (500V) 6.35 x 32mm • •
F-341 10A (1000V) 10 x 38mm • •
F-497 440mA (1000V) 10 x 35mm • • • •
F-498 11A (1000V) 10 x 38mm • • • •
F-797 315mA (1000V) 5 x 32mm •
LA-3893 2A (600V) 6.35 x 25.4mm •
LA-3898 0.25A (500V) 5 x 32mm •
BATTERIES
61-201 1.5V (LR44) •
— 1.5V (AA) • • •
— 1.5V (AAA) • • • • •
— 9V • • • • • • • • • • • • • • •
TEST LEADS
TL-34 Leads w/pin connectors •
TL-56 Test leads •
TL-95 Test leads •
TL-100 Test leads w/alligator clips • • • • • • • • •
TL-102 Silicone test leads • •
TL-104 Test leads w/large alligator clips • • • •
TL-310 Test leads • •
TL-795 Test leads •
TL-797 Test leads •
Safety in the Field
Visit our website for more technical product details,
application support, white papers, videos and software!