Specification

Noalox
®
Anti Oxidant
SDS#: ID019
Revision Date: August 22, 2016 Page 4 of 10
reconditioner. All containers should be disposed of in an environmentally safe manner and in
accordance with governmental regulations.
SECTION 8: Exposure controls/personal protection
Control Parameters:
Occupational exposure limits:
US OSHA HAZARDOUS COMPONENTS (29 CFR 1910.1200):
Permissible Exposure Limits
Substance
PEL-TWA
PEL-STEL
(15 min)
Zinc Dust
No data available
No data available
Hydrophillic Fumed
Silica
80 mg/m
3
/(% SiO2)
No data available
US ACGIH Threshold Limit Values
Substance
TLV-TWA
TLV-STEL
(15 min)
Zinc Dust
No data available
No data available
Hydrophillic Fumed
Silica
No data available
No data available
NIOSH Exposure Limits
Substance
TWA
STEL
Zinc Dust
No data available
No data available
Hydrophillic Fumed
Silica
6 mg/m
3
No data available
Appropriate engineering controls: General (mechanical) room ventilation is expected to be
adequate. Special local ventilation is recommended to keep dust below exposure limits.
Individual protection measures, such as personal protective equipment:
Eye/face protection: The use of OSHA compliant safely glasses or splash goggles are
recommended.
Skin and Hand protection: None normally required. Use neoprene gloves if necessary.
Respiratory protection: Where protection from nuisance levels of dusts are desired, use
type N95 (US) dust masks. Use respirators and components tested and approved under
appropriate government standards such as NIOSH/OSHA.
Other: An eye fountain in work area is recommended.
Thermal hazards: No data available.