Suitable power supply cables are the following types,
considering the respective necessary section of cable:
H07 RN-F, H05 RN-F, H05 RR-F, H05 VV-F, H05
V2V2-F (T90), H05 BB-F.
Terminal block
The oven is fitted with an easily accessible terminal
block which is designed to operate with a single-
phase power supply of 220 V - 230 V.
The manufacturer disclaims any liability if the safety
measures are not observed.
The replacement of electric cable must be
carried out exclusively by the service force
centre or by personnel with similar
competencies, in accordance with the
current regulations
Instructions for the Installer
The instructions given below are
designed specifically for a qualified
installer and should aid him or her to
perform all installation, adjustment,
and maintenance operations with
absolute precision and in compliance
with all current legislation and
regulations. We strongly recommend
that all operations for the installation
of your cooker be carryed out by
Qualified Personnel in accordance
with existing rules and regulations.
Electrical connection
Prior to making the electrical connection, make sure
that:
— the protection fuse and the domestic wiring
system are suitable to carry the total electric load
of the oven (see rating plate);
— your domestic wiring system has an
efficient earth connection in compliance with rules
and laws in force;
— the wall socket or the omnipole switch
used for the electrical connection can easily be
reached after the oven is built in.
This appliance is delivered without an electric supply
cable, therefore, you will have to fit to it a supply cable
with standard plug, suitable for the total electric load
shown on the rating plate. The plug is to be inserted
into a suitable wall socket. If you require a direct
connection to the electric network (mains), it will be
necessary to fit between the appliance and the mains
an omnipole switch, with a minimum gap between
contacts of 3 mm, suitable for the required load and in
compliance with rules in force. The green & yellow
ground wire must not be interrupted by the switch,
and should be 2-3 cm longer than the phase and
neutral wires. The supply cable must in all cases be
laid out in such a way as to ensure that it does not
reach at any given point a temperature 50°C higher
than the ambient temperature.