Operation Manual
SignalTEK NT 156875 Iss 2
User Guide Page 40
Wiremap
Setup
Cable Type – Cat3 UTP
- Cat3 STP
- Cat5 UTP
- Cat5 STP
- Cat5e UTP
- Cat5e STP
- Cat6 UTP
- Cat6 STP
- Cat7
- USOC
- ETH S1236
- ETH S1278
- ETH U1236
- ETH U1278
- IND. M12
- COAX RG59
Color Scheme - None
- 568A
- 568B
- USOC
- TERA
Crossover Allowed - Yes
- No
NVP - Fixed 72%
- Custom 59% - 89%
Termination Types supported
and identified by icon
Active Remote - #1 - #12
Remote Unit
Single-ended Wiremap
Tests
Faults - Open circuit by pin
- Short circuit by pin
Length of pair - Meters / Feet (Set in System Setup)
- Range 100m / 390ft
Double-ended WiremapTests
I/D - Active Remote # / Remote icon
Indications on Active Remote - Voltage Warning (>±10v on any pins)
- Pass/Fail
Indications on Remote Unit - See below
Faults - Open circuit by pin
- Short circuit by pin
- Crossed pairs
- Split pairs
- Bridged shorts
- Remote shorts
Length of pair - Meters / Feet (Set in System Setup)
- Range 100m / 390ft
Delay Skew - Per pair (ns)
Cable Tests
(continued)