Operation Manual

156840.02 SignalTEK CT 6
En
SETUP
Select SYSTEM to access the system setup:
Enter details of the test engineer and company for inclusion in the reports
Set the menu language
Set preferences for auto off, backlight, length units, date and time format
Set the date and time for inclusion in the reports
Update the software. All settings and results will be lost. Save data to USB first.
View details about the system
Reset to factory defaults. All settings and results will be lost. Save data to USB first.
Adjust the settings to be used in the tests:
Cable Type
Select number of pairs and color scheme:
If 2-Pair is selected, the Data Test will run at 100Mb/s.
If 4-Pair is selected, the Data Test will run at 1Gb/s
Shield Type
Select how the shield will affect the Wiremap Test:
UTP Wiremap Test will only pass if the cable shield is not connected
STP Wiremap Test will only pass if the cable shield is connected
UTP/STP Shield will not affect the result of the Wiremap test
Nominal Velocity of Propagation (NVP)
Accurate length measurement relies on correct setting of the Nominal Velocity
of Propagation (NVP) for the cable to be tested.
Shows an illustration of the cable based on the selected cable type
SignalTEK CT can be used together with a compatible tone probe (available from
IDEAL) to identify and trace cables. SignalTEK CT can generate various types of tone on
various combinations of pins. Choice of tone type and pin connection is best determined by
experiment, to achieve the best results with a particular probe type and in a particular cable
situation.
Select the required report style:
Format
o PDF for graphical reports that can be viewed or printed using a PDF viewer
o CSV for editable reports that can be opened in a spreadsheet
Size
o FULL to include all details (larger file, takes longer to upload)
o SUMMARY (smaller file, takes less time to upload)
Include length measurement in the reports if required