Operation Manual
72
CHAPTER 8
Fiber Testing with FiberTEK™ FDX
8.1. Safety Precautions
WARNING!
NEVER look directly into the port of measuring adapter, at connector surface, open fiber
ends or into couplers. There is a risk of light emerging from the fiber that is not visible,
which could permanently damage your eyes.
If you are not sure whether the device is switched on or whether the fiber transmits light,
for safety reasons always assume that the device is active.
Handle bare fibers properly; there is a risk of injury from fiber splinters.
Protect your eyes when working with bare fibers; fiber splinters could permanently damage
your eyes.
Never let fiber scraps lie openly and never dispose of them loosely in normal waste
containers; there is a risk of injury from fiber splinters.
CAUTION!
When connecting the measuring adapter to a light-conducting line, the maximum
measuring range must be observed (see specifications of individual modules). Exceeding it
could result in damages to FiberTEK™ FDX modules.
8.2. Notes on Cleaning Measuring Adapter and Patch Cord
NOTE:
Before connecting cable adapter to FiberTEK™ FDX adapter, ensure that the plugs of cable
connectors are clean.
Clean ferrules of measuring adapter only with dry, lint-free, non-abrasive materials.
The plugs can be cleaned with suitable fiber cleaning cloths or cleaning pens. IDEAL
recommends cleaning set #1219-00-1621 to care for the modules and patch cord.