Use And Care Manual
3
4
61-486
Volt SenseRange Min Max
Press 2 Sec
PEAK HOLD
Smart
HOLD
A
Auto
V
LoZ
OFF
MAX
10A
FUSED
MAX
600mA
FUSED
600V CAT IV
1000V CAT III
mA COM
V Ω
TRUE RMS
Hz
Hz
V
ac+dc
ac+dc
ac+dc
ac+dc
V
mV
mA
A
Ω
3
Meter Description
Front Panel Illustration
1. LCD display : 6000 counts
2. Push-buttons.
3. Rotary switch to turn the Power On / Off and select the
function.
4. Input Terminal for A.
5. Input Terminal for V,Ω, , Hz, °C/F° functions.
6. Common (Ground reference) Input Terminal.
7. Input Terminal for mA.
1 Display
2 Buttons
3 Rotary
Switch
5 V, Ω,
,
C°/F°
Input
6 Common
Input
7 mA Input
4 A Input
Risk of Danger. Important Information. See Manual.
Hazardous voltage. Risk of electrical shock.
Application around and removal from Hazardous Live
conductors is permitted.
AC (Alternating Current)
DC (Direct Current)
Earth Ground
CAT II
Measurement Category II applies to test and measuring cir-
cuits connected directly to utilization points (socket outlets
and similar points) of the low-voltage MAINS installation
CAT III
Measurement Category III applies to measuring circuits
connected to the distribution part of the building’s low-
voltage MAINS installation
CAT IV
Measurement Category IV applies to test and measuring
circuits connected at the source of the building’s low-
voltage MAINS installation