Use And Care Manual
15
16
Low Battery and Battery Replacement
Replace the battery as soon as the low battery indicator
appears to avoid false readings. Refer to the following figure
to replace the battery.
Caution
Remove test leads from the Meter before opening the battery
cover or meter case.
9V Battery
Ba
ttery Cover
Screw
Specifications
General Specifications
Maximum voltage applied to any terminal:
1000 Vac rms or 1000 Vdc. rms
Display: 6000 counts.
Polarity Indication:
Automatic, positive implied, negative indicated.
Overrange Indication: OL
Battery Life: 150hours ALKALINE Battery (No Backlight)
Low Battery Indication:
Voltage drops below operating voltage, will flash.
Power Requirement: 9V battery
Auto Power Off: 20 minutes.
Operating Temperature: -10 ~10°C
10°C ~ 30°C (<80% RH),
30°C ~ 40°C (<75% RH),
40°C ~ 50°C (<45%RH)