Installation Instructions
Page 6 
(5) Resistance (for 61-340 / 61-342) 
Range Resolution  Accuracy 
Over voltage 
protection 
400.0Ω ** 0.1Ω  ±(1.2% reading + 5 digits) 
4.000KΩ 1Ω 
40.00KΩ 10Ω 
400.0KΩ 100Ω 
±(1.0% reading + 2 digits) 
4.000MΩ 1KΩ  ±(1.2% reading + 2 digits) 
40.00MΩ *** 10KΩ  ±(2.0% reading + 5 digits) 
600Vrms 
Open circuit Voltage: 0.44V approx. 
** < 5 digit of reading rolling. 
*** < 2% of reading rolling. 
(6) Diode Check and Continuity (for 61-340 / 61-342) 
Range Resolution  Accuracy 
Max. Test 
Current 
Max. Open 
Circuit Voltage
  1mV  Not specified  <1mA, approx. 2.5V, approx. 
Overload Protection: Not specified 
Continuity: Built-in buzzer sounds when resistance is less than approximately 120 Ω with a response 
time of approximately 100 msec. 
(7) Capacitance (for 61-340 / 61-342) 
Range Resolution  Accuracy 
Over voltage 
Protection 
40.00nF 10pF 
±(3.0% reading + 10 digits) 
400.0nF 100pF 
4.000μF 1nF 
40.00μF 10nF 
±(3.0% reading + 5 digits) 
400.0μF 100nF 
4000μF ** 10μF 
±(20% reading + 5 digits) *** 
600Vrms 
** In this range the reading may be rolling within specification. 
*** Specify reading < half full scale of range. 
 Note: The meter selects the proper range automatically. Each measurement takes about one 
second per range. Readings >40.00μF will take ≈ 8 seconds or greater 
Form Number TM61340-2  Rev 3 January 2008   