Installation Instructions
Page 3 
SPECIFICATIONS 
All specifications are warranted unless noted typical and apply to the 61-340 & 61-342 
Stated accuracies are at 23°C±5°C at less than 75% relative humidity and without the battery indicator 
displayed. 
General specifications 
Characteristics Description 
Display count  3 3/4 digit liquid crystal display, max count 3999 
Numeric update rate  2.5 times / sec 
Polarity display  Automatic 
Over range display  “OL” is displayed 
Low battery indicator       is indicated 
Automatic power-off time    Automatic power off ≈ 10minutes 
Power source 
9.0V battery: types- NEDA 1604, JIS006P, IEC6F22   
for both 61-340 and    61-342 
Maximum input voltage  1000Vrms CAT III between V and COM 
Maximum floating voltage 
1000Vrms CAT III between any terminal and earth ground
Maximum input current  400mA between µA /mA and COM 
Overload protection mA connector  500mA (500V) fast blow fuse. 
Overload protection 10A connector  10A (500V) fast blow fuse. 
V connector  V , V , Ω,  ,  ,  , Hz 
µA /mA connector  µA, mA, Temp 
Temperature Coefficient  0.1×(Spec. Accuracy) per °C, <18°C or >28°C 
Battery Life 
Alkaline 9V, ≈ 200 hours for 61-340 
Alkaline 9V, ≈ 150 hours for 61-342 
Form Number TM61340-2  Rev 3 January 2008   