Welder User Manual
Form Number  2  TM61340-2 Rev  November 2007 
Page 4 
Measurement Characteristics 
Accuracy is ±(% reading + number of digits) at 23°C ± 5°C, less than 75% R.H. 
(1) DC Volts(for 61-340 / 61-342) 
Range Resolution  Accuracy 
Over voltage 
protection 
400.0mV  0.1mV  ±(0.8% reading + 3 digits) 
4.000V 1mV 
40.00V 10mV 
400.0V 100mV 
±(0.8% reading + 1 digits) 
1000V  1V  ±(1.0% reading + 3 digits) 
1000VDC or 750VAC 
Input Impedance: 10MΩ 
 (2) AC Volts (61-340/61-342) 
Range Resolution  Accuracy 
Over voltage 
protection 
400.0mV 0.1mV 
±(1.2%+8) 
4.000V 1mV 
40.00V 10mV 
400.0V 100mV 
1.0% + 5 
750V 
1V 
±(1.2%+5) 
1000VDC or 750VAC 
Input Impedance: 10MΩ 
AC Conversion Type: 61-340: Average sensing rms indication calibrated to the sine wave input. 
61-342: AC conversion is True RMS responding, calibrated to a sinusoidal 
waveform 
Crest Factor: C.F. = Peak/RMS 
 For non-sinusoidal waveform, C.F. > 2 add ±1% to accuracy, 
Frequency response: 40~400Hz 
 (3a) DC micro-amp and milli-amps (for 61-340 / 61-342) 
Range Resolution  Accuracy  Input Protection 
400.0µA 0.1μA 
4000µA 1μA 
±(0.8% reading + 2 digits)* 
40.00mA 10μA 
400.0mA 0.1mA 
±(0.8% reading + 3 digits)* 
500mA, 250V Fast 
Blow Fuse 
 Overload Protection: mA Input: 500mA, 250V Fast Blow fuse. (61-340 / 61-342) 