Welder User Manual
Form Number  2  TM61340-2 Rev  November 2007 
Page 10 
Required Equipment 
Required equipment is listed in Table B. If the recommended models are not available, equipment with 
equivalent specifications may be used. 
Repairs or servicing should be performed only by qualified personnel. 
Table B. Required Equipment 
Equipment  Required Characteristics  Recommended Model 
Calibrator 
AC Voltage Range: 0 
~ 750V AC 
Accuracy: ±0.07% (Basic) 
Frequency Range: 40 
~ 1KHz 
Accuracy: ±2% 
DC Voltage Range: 0 
~ 1000V DC 
Accuracy: ±0.006% (Basic) 
Current Range: 0 
~ 10A 
Accuracy: AC (40Hz to 1KHz): ±0.08% (Basic) 
DC: ±0.02% (Basic) 
Frequency Source: 1.00Hz 
~ 10MHz 
Accuracy: ±0.001% 
Amplitude: 0.5V p-p 
~ 5.0V p-p (square wave) 
Accuracy: ±5% 
Resistance Range: 1Ω 
~ 100MΩ 
Accuracy: ±0.03% (Basic) 
Capacitance Range: 1pF 
~ 10mF 
Accuracy: ±0.10% (Basic) 
Fluke 5500 or Wavetek 
9100 Calibrator or 
equipment 