Installation Instructions

3
Features:
Vibration Mode with indicator movement
Auto-Switching Voltage/Continuity
Technology (61-076, 61-080)
Independent solenoid and electronic circuitry
design provides back-up voltage indication
for added safety
Low Impedance
Replaceable Test Leads
Shielded probe tips
Ultrasonically welded and o-ring sealed for
added durability
• Indicates:
• 100-600V AC/DC (61-065, 61-067)
5-600V AC/DC (61-076, 61-080)
To Measure AC/DC Voltage:
Ensure that the plug for the test leads is fully
seated into the banana jacks.
Connect the tester in parallel with the load or
circuit.
The tester indicates the voltage type, DC
polarity, and the voltage level.
Warning
Do not exceed duty cycle specified on tester.
To Test for Continuity (61-080, 61-076):
Ensure that the plug for the test leads is fully
seated into the banana jacks.
Test for continuity by connecting the tester to
the de-energized circuit.
If circuit has <500kΩ, the Continuity LED
lights.
Reversing prods on the circuit under test
verifies continuity versus low voltage +DC.