Installation Instructions

Do not use around explosive gas, dust, vapor,
amperage or in damp or wet environments.
Do not apply more than the rated voltage to
the tester.
Remove the test leads from the input jacks
before measuring current.
Remove the test leads from the meter prior to
removing battery cover. (61-076, 61-080)
Do not use without the battery and battery
cover properly installed. (61-076, 61-080)
Do not attempt to repair this unit as it has no
user-serviceable parts.
Never ground yourself when taking electrical
measurements.
Connect the black common lead to ground
or neutral before applying the red test lead to
potential voltage. Disconnect the red test lead
from the voltage first.
Keep fingers behind the guard rings of the
probe tips.
Voltages exceeding 30VAC or 60VDC pose a
shock hazard so use caution.
CAUTION
To protect yourself, think “Safety First”:
Comply with local and national safety codes.
Use appropriate personal protective equipment
such as face shields,
insulating gloves, insulating boots,
and/or insulating mats.
Before each use:
- Perform a continuity test by touching the
test leads together to verify the functionality
of the battery and test leads.
- Use the 3 Point Safety Method. (1) Verify
meter operation by measuring a known
voltage. (2) Apply meter to circuit under test.
(3) Return to the known live voltage again to
ensure proper operation.
Always work with a partner.