14.2 THE MAINTENANCE OF PROFESSIONALS
The maintenance of professionals can only be carried out by the professionals from the
factory.
14.2.1 If the imbalance value of tested wheel has obvious errors and does not
improve after self-calibrating, this proves the parameter in the machine has
altered, so the user should ask for professionals.
14.2.2 The replacing and adjustment of pressure sensor should be operated
according to the following methods, and the operation should be carried out by
professionals.
THE STEPS ARE AS FOLLOWS:
1. Unlash the No.1, 2,3,4,5 nuts.
2. Dismantle the sensor and nut.
3. Replace No.6, 7 the sensor organ.
4. Install the sensor and the nut according to the Fig 14-1. (Pay attention to the
sensors direction.)
5. Tighten No.1 nut emphatically.
6. Tighten the No.2 nut to make the main axis and the flank of cabinet, and then
emphatically tighten the No.3 nut.
7. Tighten the No.4 nut (not too emphatically), then tighten No.5 nut.
14.2.3 The replacing of circuit board and the sensor on it should be carried out by
professionals.
Fig 14-1