Product Manual

43
May 2019
TCWB-PSC206M-iDEAL
9.3 As per Fig 9-2, clamp a 100 gram counterweight on anywhere of outside of rim,
manually rotate wheel, when display is off, move hands away to enter next step, Press
[SET] key to exit.
Fig 9-2
9.4 As per Fig 9-3, wheel stops rotating, calibration ends. Demount tire, now balancer
is ready to work.
Fig 9-3
10. GRAM-OZ CONVERSION OPERATION
This operation for counterweight weight unit conversion (Gram-Oz)
1. Press [a-] or [a+] key, Fig 7-1.
2. Press [FINE] and hold it, then press [a+] and [a-] keys, weight unit is converted to
Oz.
3. Again press [FINE] + [a+] + [a-] keys, weight unit is converted to Gram.
4. Repeat 10.3 operation to convert weight unit between Gram and Oz.
11. OTHER FUNCTION SETTINGS
11.1 MINIMUM VALUE DISPLAY SETTINGS
Select minimum display value, if wheel imbalance value is less than setting value,
displayed result will be 0. Press FINE key, real imbalance value can be shown.
Press [FINE] + [MODE] keys, show Fig 11-1 which means if imbalance value is less
than 5 gram, displayed result will be 0, press [b-] or [b+] key to set minimum display
value : 5,10 or15. Press [a+] key to save current setting and enter next step.
NOTE: WHEN DOING SELF-CALIBRATION, INPUT DATA OF RIM MUST BE
CORRECT, 100 GRAM COUNTERWEIGHT MUST BE CORRECT, OTHERWISE
SELF-CALIBRATION RESULT WILL BE WRONG, WRONG SELF-CALIBRATION
WILL BE MAKE BALANCER MEASURE PRECISION DECLINE.