Product Manual
41
May 2019
TCWB-PSC206M-iDEAL
7.9 RECALCULATION
Before wheel balance testing, sometimes operator may forget input current data of rim.
Data can be inputted after wheel balance testing. Then it is not necessary to make
balancing test again. Operator only needs to press [SET] key, system can re-calculate
imbalance value with new data. Under interface showing imbalance value, press [SET]
key to check current inputted data of rim.
8. IMBALANCE OPTIMIZE
If wheel imbalance value over 30 gram, system will be display “OPT”, indicate to carry
out imbalance optimize.
Imbalance optimize have two operation method:
8.1 ALREADY DISPLAY BALANCE VALUE
If already finish balance testing, when you need process imbalance optimize, press
OPT key, display Fig 8-1.
Fig 8-1
Use chalk mark a reference point on the flange and rim and tire, use tire changer to
exchange rim and tire by 180°.
Re-install wheel on the balancer and make sure mark of reference point between the
flange and rim must be on the same position. Quickly rotate wheel to balance wheel,
after rotation stop, display Fig 8-2.
Fig 8-2
As per above Fig 8-2, left display shows percent of optimize. If before optimize static
value is 40 gram, optimized percent is 85%, so after optimize static value only 6 gram
remain (15% x 40 gram = 6 gram).
Slowly rotate wheel by hand, when both end sides two of position indicator light flash
(Fig 8-3), use chalk to make a mark on the tire.