Product Manual
36
May 2019
TCWB-PSC206M-iDEAL
data. Slowly rotate wheel, when inside position indication LEDs all light, (Fig 5-1
(10) ), at the 12 o’clock position of rim inside, clamp weights equal to value
shown on the left side display (Fig 7-3). Then slowly rotate wheel, when outside
position indication LEDs all light, (Fig 5-1 (11) ), at the 12 o’clock position of rim
outside, clamp weights to equal to value shown on the right side display (Fig 7-
4). Rotate wheel by hand again, move hand away when display is off. When both
side display are on, wheel stops and balancing is completed.
Fig 7-3 Fig 7-4
7.3 STATIC (ST) BALANCING MODE DATA INPUT METHOD & BALANCING
OPERATION
(ST) mode is suitable for rims on which weights only can be applied at the middle
position, such as motorcycle rims.
Under normal mode, measure diameter d value (Fig 7-5), press [d-] or [d+] to input d
value. (a value and b value can be any value). Press [MODE] key to make ST mode
indication light on, enter static (ST) balancing mode, mode indication as following
figure.
Fig 7-5
Input rim data, manually rotate wheel, when display shows “RUN ---”, move hand away
to let wheel rotate. Then right display shows ST and left display shows static imbalance
amount as Fig 7-6. After wheel stops rotating, slowly rotate wheel, when inside
position indication LEDs (Fig 5-1 (10)) and outside position indication LEDs (Fig 5-1