7. RIM DATA INPUT METHODS & BALANCING OPERATION
7.1 THE POWER-ON STATE OF THE MACHINE
After the power-on of the machine, it starts initialization automatically. The initialization
will be finished after two seconds. The machine enters normal dynamic balancing
mode (clamp counterweights on the both rim edge) automatically, as in Fig 7-1, ready
for input data of rim.
Fig 7-1
7.2 DATA OF WHEEL INPUT METHOD FOR NORMAL DYNAMIC BALANCE MODE
AND WHEEL BALANCING OPERATION
7.2.1 After power is on, machine enters normal balancing mode, as below.
7.2.2 Input rim data: Move scale to make handle head touch rim edge inner
position as Fig 7-2, get value a, put back scale. Push [a-] or [a+] to input a value.
Fig 7-2
7.2.3 Input rim width: Get rim width data showing on rim, or measure rim width by
caliper, push [b-] or [b+] to input b value.
7.2.4 Input rim diameter: Get rim diameter data showing on rim, or measure rim
diameter by caliper, push [d-] or [d+] to input d value.
7.2.5 Balancing operation against normal dynamic balancing mode: Input rim
data, manually rotate wheel, when display shows “RUN ---”, move hand away to
let wheel rotate. When display shows “STOP”, wheel stops and display shows