Product Manual
iDEAL Open Front Paint Spray Booth (PSB-AFOFB1388-AK)
20
4.10 TUBEAXIAL FAN
The fan and motor assembly bolts to the top of the Exhaust Chamber Roof Panel
4.11 OPTIONAL - EXHAUST DUCT KIT &INSTALLATION
If equipped with optional exhaust ductwork, it is recommended to
have this professionally installed.
(Storm Collar & Roof Flange sold separately)
To assemble the ductwork:
1. Bolt pipe with connecting ring to the exhaust fan.
2. Remaining ductwork is crimped on one end to interlock with
the nextsection.
3. Your ARV (automatic damper) will be mounted on top.
4. Storm collar will attach to duct above flashing to make it
weatherproof.
Special Note:
Where more than 25 ft. of piping is required, static pressure
(resistance) is increased, and the air flow may be hindered when
using the standard exhaust unit recommended for use with the
booth. Where a piping arrangement of an unusual nature is
necessary or where two or more elbows are used, a similar condition
may exist. Therefore, if either ofthese situations arises, contact the
iDEAL Rep. for recommendations. Exhaust piping, including the
canopy (if used), should extend a minimum of 6’ ft. above the
highest point of building. There should be an access door just above