Product Manual
10
Oct. 2018
M-2200IEH-XR
2. Power Connection
Before power connection is made, check your power supply outlet to ensure it’s in accordance with
the requirements of the lift.
a. Connect lift’s electrical plug to a 110V-60Hz, 1Ph, 20A power supply outlet. Protection against power
surges shall be provided by the user.
3. Starting Up (No Load on Lift)
a. Using the Remote Pendant Control, raise the platform to full height by pressing the
(GREEN) UP↑button. (Fig. 2)
b. Lower the lift to floor by pressing the (BLUE) DOWN↓button.
c. With no load on lift, cycle up and down several times to get the air out of the hydraulic
system. (Wait 2 minutes between cycles)
d. After cycling lift, raise and secure at almost full height by pressing the (BLACK)
PARKING button to secure lift in the locking position, as the electronic latches will
automatically engage. (Securing lift at full to mid height is best for Assembly.)
Fig. 2
4. Assembly
a. Attach or insert the front Wheel Stop Bar(s), Tie-Down Eyelets, Retractable Ramp & Stabilizer / Balance
Bars - (Figs 3, 4 & 5)
Fig. 3 Fig 4 Fig. 5
5. Change the Tank Plug
a. Remove ‘black’ shipping Plug from reservoir tank and replace with the ‘brass’ ventilating Plug - (Figs 6 & 7)
Fig. 6 Fig. 7
The Lift is now ready for Operation