User manual
Copyright © 2010, International Technologies & Systems Corporation. All Rights Reserved
43 of 66
ID TECH EzWriter
Command: Shift to AMC protocol
Command code: <ESC> AMC
Hex code: 1B 41 4D 43
Response: <ESC> 0 :
Description: This command is used to shift the protocol to AMC and perform a reset in
AMC protocol.
Data Formats
[Data Block] format
[Card Data] format
Char Data
Char Code <ESC>1 [string1] <ESC>2 [string2] <ESC>3 [string3]
Hex Code 1B 01 [string1] 1B 02 [string2] 1B 03 [string3]
[Status Byte] format
[Raw Data Block] format
Start Field EzWriter Data
Field
Ending Field
Command
Code
<ESC>s [Raw Data] ?<FS>
Hex code 1B 73 [Raw Data] 3F 1C
[Raw Data] format
Raw Data
Char Code <ESC>1[L1][string1] <ESC>2[L2][string2]
<ESC>3[L3][string3]
Hex Code 1B 01[L1][string1] 1B 02[L2][string2] 1B 03[L3][string3]
Note: [L1],[L2],[L3] is the length of [string1],[string2],[string3]
None available or none data on tracks does not output when swipe of card
Start Field EzWriter Data
Field
Ending Field
Commend
Code
<ESC>s [Card data] ? <FS>
Hex code 1B 73 [Card data] 3F 1C
Status Description Hex ASCII
Ok Read, Write, or Command ok 30 0
Read /
Write
Error
Track 1 error 31 1
Track 2 error 32 2
Track 1 and Track 2 error 33 3
Track 3 error 34 4
Track 1 and Track 3 error 35 5
Track 2 and Track 3 error 36 6
Track 1, Track 2 and Track 3 error 37 7