IR Intelligent Speed Dome Installation Manual Version 1.0.
Table of Contents 1 INSTALLATION PREPARATION ........................................................................ 1 1.1 Basic Requirement ................................................................................................................................ 1 1.2 Installation Check .................................................................................................................................. 1 1.3 Cable Preparation ......................................................
4 APPENDIX Ⅰ LIGHTNING PROOF AND SURGE PROTECTION (OUTDOORS) 17 4.1 5 Lightning Protection (Indoors)............................................................................................................ 17 APPENDIX Ⅱ ABOUT RS485 BUS ................................................................... 19 5.1 RS485 Bus Main Feature ................................................................................................................... 19 5.2 RS485 Bus Transmission Distance ...........
Welcome Thank you for purchasing our speed dome! Please read the following safeguards and warnings carefully before you install or use the product! iii
Important Safeguards and Warnings Safety Measures 1. Qualified Engineer Needed The installation engineer or maintenance engineer shall have corresponding CCTV system installation certificate or maintenance qualification certificate. The installation engineer or maintenance engineer shall have qualification certificate for work at height.
. All the examination and repair work should be done by the qualified service engineers. We are not liable for any problems caused by unauthorized modifications or attempted repair. Note 1. Safety Transportation Heavy stress, violent vibration or water splash are not allowed during transportation, storage and installation. This series product must use split type package during the transportation.
Do not use gasoline, dope thinner or other chemical material to clean the shell. It may result in shell transfiguration or paint flake. Do not allow the plastic or rubber material to touch the shell for a long time. It may result in paint flake. It is highly recommended to use the product with a lightning-proof device, which can realize better lightning-proof effect.
1 Installation Preparation 1.1 Basic Requirement All installation and operation here should conform to your local electrical safety codes. Make sure if the application location of the speed dome conforms to the installation requirements. Please contact your local dealer if there is any confusion. Please use the product according to the environment.
2 Install IR Intelligent Speed Dome 2.1 Check Accessories Before installation, please check the accessories one by one according to the packing list. Please make sure all the components listed are includes. 2.2 Open Device Take out the speed dome and refer to Figure 2-1 for its appearance. Figure 2-1 Note It is forbidden to make the front part of speed dome face ground when placing the device, which is to avoid damaging the front glass, lens and other optical components.
Figure 2-2 2.3 Reset Button, Micro SD Card Slot You can see the reset button and Micro SD card slot on the PTZ mainboard after opening the speed dome cover, which is shown in Figure 2-3.
2.3.1 Use Reset Button Long press the reset button (more than 10 seconds) to reset the device. 2.3.2 Install Micro SD Card Micro SD card is used for data storage. Micro SD card slot is located on PCB inside the dome body; you can see it after you open the speed dome cover, which is shown in Figure 2-3. The installation steps of Micro SD card are shown as follows. Step 1 Hold the Micro SD card, pay attention that the golden finger of the card faces inward, which means it faces the PCB.
It is prohibited to pull the cable to lift the speed dome when moving the device, the wrong way of carrying device is shown in Figure 2-5. Figure 2-5 2.4.1.
Figure 2-6 2.4.1.3 Connect Alarm Cable The alarm cable connection and config steps are shown as follows: Step 1 Connect alarm input device to the ALARM IN and ALARM GND of the user cable. Step 2 Connect alarm output device to the ALARM OUT and ALARM COM of the user cable, alarm output is the relay switch output. Step 3 Open the device WEB interface, make corresponding settings to the alarm input and output device in “Setup > Event > Alarm Setup”.
2.4.2.1 Install Device with Quick Mounting Connector Step 1 Fix the quick mounting connector on the bracket, and pull out the wall cable from the quick mounting connector. Step 2 Fix one side of the safety rope on the speed dome and the other side on the quick mounting connector. Step 3 Align the flange edge with that of the quick mounting connector; push the speed dome into the quick mounting connector, which is shown in Figure 2-7.
Figure 2-8 Step 6 Check if the screws on the quick mounting connector are firmly tightened, the safety buckle is reliably connected and the speed dome is firmly fixed. The speed dome installation is completed after confirmation, which is shown in Figure 2-9.
Figure 2-9 2.4.2.2 Install Device without Quick Mounting Connector Step 1 Fix one end of the safety rope on the speed dome and the other end on the bracket hook, which is shown in Figure 2-10.
Figure 2-10 Step 2 Connect Speed dome cable and wall cable well, make sure both are waterproof. Please refer to “2.4.1 Speed Dome Cable” for more details about cable connection. Step 3 Align the flange edge with that of the bracket; push the speed dome into the bracket, twist three stainless screws into the corresponding screw holes of the flange, and then use inner hex tool to fix three stainless screws, which is shown in Figure 2-11.
Figure 2-11 Step 4 Check if the screws on the bracket are firmly tightened, the safety buckle is reliably connected and the speed dome is firmly fixed. The speed dome installation is completed after confirmation, which is shown in Figure 2-12.
Figure 2-12 12
3 Wall-mounted Bracket Installation 3.1 Mounting Component and Dimension The appearance of wall-mounted bracket is shown in Figure 3-1, refer to Figure 3-2 for dimension..
Figure 3-2 3.2 Installation Steps of Wall-mounted Bracket 3.2.1 Installation Conditions Wall-mounted speed dome can be installed on hard wall structure both indoors and outdoors. The wall needs to meet the following installation conditions. The wall should be thick enough to install expansion bolts. The wall shall sustain at least 8x weight of the speed dome, bracket and so on. 3.2.
Figure 3-3 Step 2 Insert the expansion bolts into the holes you just dug. Step 3 Use four hex nuts and flat gasket to twist the wall-mounted bracket into the expansion bolts. Step 4 Install the speed dome on the wall-mounted bracket, which is shown in Figure 3-4. Please refer to “2.4.2 Install Speed Dome” for the installation modes of the device.
Figure 3-4 16
4 APPENDIX Ⅰ LIGHTNING PROOF AND SURGE PROTECTION 4.1 Outdoors This series speed dome adopts TVS lighting protection technology. It can effectively prevent damages from various pulse signals below 6000W, such as sudden lighting and surge. While maintaining your local electrical safety code, you still need to take necessary precaution measures when installing the speed dome in the outdoor environment.
The yellow and green GND wire or GND screw of the speed dome should be reliably connected by several strands of copper wire with no less than 25mm²and indoor equipotential GND terminal. Please refer to Figure 4-2 for lightningproof installation mode.
5 APPENDIX Ⅱ ABOUT RS485 BUS 5.1 RS485 Bus Main Feature RS485 is semi duplex communication cable of impedance 120Ω. Its max load amount is 32 effective loads (including main control device and devices to be charged). 5.2 RS485 Bus Transmission Distance When we take 0.56mm (24AWG) twisted-pair as communication cable, the max transmission distance (theoretically) are listed below (according to different baud rates).
Figure 5-2 5.4 RS485 Bus FAQ Phenomenon Speed dome can run selfdiagnosis but I cannot control it.
6 APPENDIX Ⅲ THE RELATIONSHIP BETWEEN AC 24V CABLE DIAMETER AND TRANSMISSION DISTANCE The max transmission distance is recommended when the cable diameter is fixed and AC 24V voltage loss rate is lower than 10%. For the AC power supply devices, the max allowed voltage loss rate is 10%. For example, a device with rated power of 20W, installed 141 feet (42m) away from the transformer, the minimum wire diameter needed is 0.8000mm. mm Feet(m) 0.8000 1.000 1.250 2.
7 APPENDIX Ⅳ WIRE GAUGE REFERENCE SHEET Metric bare wire diameter (mm) 0.050 0.060 0.070 0.080 0.090 0.100 0.110 0.130 0.140 0.160 0.180 0.200 0.230 0.250 0.290 0.330 0.350 0.400 0.450 0.560 0.600 0.710 0.750 0.800 0.900 1.000 1.250 1.500 2.000 2.500 3.000 AWG SWG 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 16 15 12 / / 47 46 45 44 43 42 41 39 / 37 / 35 / 33 31 30 29 28 / 24 23 22 / 21 20 19 18 / 14 / / Bare wire cross section (mm2) 0.00196 0.00283 0.00385 0.00503 0.