Manual

Circulating Air Blower
To access or remove the blower motor use the following steps.
1. Turn electric power OFF.
2. Remove the blower access panel.
3. Unplug the wires connected to the speed tap block if neces-
sary, noting the location of each wire for re-installation.
4. Slide entire housing toward you.
5. Visually inspect the blower wheel for accumulations of dirt or
lint. Clean the compartment and the blower wheel. If accu-
mulation is excessive on blower wheel, or does not easily
remove, it may be necessary to remove and disassemble the
blower assembly for proper cleaning.
6. Oil blower motor if needed.
CAUTION
Do NOT use 3 in 1 oil, penetrating oil, WD40 or similar oils to
oil motor bearings.
Oil the blower motor by adding several drops of SAE 10W30 to
each motor bearing. The blower motor should be oiled after five
years of operation and every five years thereafter.
7. When finished, reassemble in reverse order.
12 426 01 1005 O0