Installation guide

READ
REVERSE
SIDE
FIRST
TOP
READ
REVERSE
SIDE
FIRST
READ
COMPLETE
SAFETY
INSTRUCTIONS
AND
INSTALLATION
TEMPLATE
BEFORE
STARTING
TEMPLATE
MUST
BE
LEVEL
1
Place
unit
on
flat
surface and
pull
front
cover
up on
right
side.
It
snaps
loose.
Remove
evaporative
assembly.
6
Reinstall
the
evaporative
assembly
complete
with
the
evaporative
media
by
fitting
the
drain
tube
into
the
round
receptacle
at
the
bottom
of
the
unit.
Push
the
assembly
in
at
the top
against
the
beveled
tabs.
Replace
the front
cover
and
attach
nameplate
with
appropriate
brand
name.
9
Connect
tubing
from
the
saddle
valve
to
the
inlet
side
of
the
solenoid
valve
using
1/4"
0.D.
copper
tubing
(not
furnished).
DOUBLE
WRENCH
TO
PREVENT
LEAKING!
2
The
unit
is
assembled
for
left
side
discharge.
If
right
discharge
is
necessary,
remove
the
right
and
left
screws
from
the
unit
interior
side
walls
and
exchange
the
two
sides.
Reassemble
with
screws.
©
7
~~
DISCONNECT
ELECTRICAL
POWER
TO
FURNACE
BEFORE
PROCEEDING.
The
Humidifier
Control
is
designed
for
low
voltage
service
to
control
humidification
equipment.
An
increase
in
relative
humidity
expands
the
nylon
ribbon
that
opens
the
control
switch
to
stop
operation
on
the
humidifier.
A
decrease
in
relative
humidity
reverses
the
process
and
closes
the
control
switch.
Install
the
Humidifier
Control.
TO
INSTALL
ON
COPPER
OR
PLASTIC
PIPE
a)
Place
rubber
gasket
in
center
of
hole
in
top
saddle
clamp.
Place
top
and
bottom saddle
clamp
around
water
pipe.
Using
bolts,
tighten
saddle
clamps,
evenly
-
clamps
should
be
parallel
-
DO
NOT
over-tighten.
b)
Screw
valve
body
into
opening
in
top
saddle
clamp
and
tighten.
c)
Tighten
gland
nut
onto
valve
body.
d)
Install
1/4”
water
supply
line
from
humidifier
using
compression
fittings.
e)
You
are
now
ready
to
pierce
the
pipe.
Turn
handle
until
spindle
is
firmly
seated
into
valve
body.
The
water
pipe
is
now
fully
pierced.
Turning
spindle
in
shuts
valve
off.
Open
valve
completely
for
normal
operation.
3
Use
this
template
for
marking
the
unit
opening
to
be
cut
in
plenum.
Draw
a
level
line
at
least
three
inches
above
furnace
jacket
for
clearance
of
the
drain
line
and
solenoid
valve.
Tape
template
in
position
and
trace
around
entire
outside
edges.
Remove
template
and
accurately
cut
the
plenum
opening
accordingly,
being
careful
to
avoid
injury
from
sharp
edges.
LOCATION
1.
Locate
Humidifier
Control
on
inside
wall
of
living
area
approximately
5’
above
floor,
or
in
the
furnace
return
air
plenum
or
duct.
For
return
air
plenum
installation
use
Humidifier
Control
Adapter
Plate,
Fast
part
#
4463
{Not
Included)
.
Do
not
locate
control
in
the
direct
path
of
furnace
discharge
air
or
drafts
from
open
doors
and
windows.
Do
not
install
where
operation
might
be
affected
by
lamps,
sunlight,
fireplace
registers,
radiators,
concealed
air
ducts
and
pipes,
or
room
occupants.
The
basic
rules
for
location
of
thermostats
also
apply
to
Humidifier
Control
TO
INSTALL
ON
STEEL
OR
BRASS
PIPE
a)
Shut
off
water
supply.
Open
any
faucet
to
relieve
water
pressure.
b)
Drill
3/16”
diameter
hole
into
pipe
where
saddle
valve
will
be
placed.
c)
Place
rubber gasket
in
center
of
hole
in
top
saddle
clamp.
d)
Place
top
saddle
clamp
assembly
over
hole
so
that
lance
fits
into
hole,
e)
Place
top
and
bottom
saddle
clamp
around
water
pipe.
f)
Screw
valve
body
into
opening
in
top
saddle
clamp
and
tighten.
g)
Tighten
gland
nut
onto
valve
body.
h)
Install
1/4"
water
supply
line
from
humidifier
using
compression
fittings.
NOTE:
For
pipe
over
1"
O.D.,
use
1/4"-20,
1-3/4"
long
bolts.
4
Place
the unit
into
the
plenum
opening
so
that
the
locking
tabs
on
the
bottom
are
closed
down
onto
the
lower
sheet metal
edge.
While
holding
the
unit
in
place,
install
two
screws
at
the
top
of
the
unit
interior.
*
GENERAL
INSTRUCTIONS
1.
DO
NOT
ATTEMPT
TO
REPAIR
OR
RECALIBRATE
CONTROL.
Controls
requiring
service
should
be
returned
to
your
distributor.
Control
must
be
installed
using
24
volts!
Make
sure
no
bare
wires
are
exposed
or
insulation
damaged.
Insulation
on
wire
should
extend
to
head
of
binding
screws.
-
Make
sure
all
splices
are
mechanically
and
electrically
secure.
To
rernove
dirt
or
other
foreign
matter
from
nylon
ribbon
and control
interior,
dust
lightly
with
a
fine,
soft
brush.
1
0
Connect
1/2”
LD.
plastic
hose
(not
furnished)
from
unit
to
floor
drain.
Be
sure
drain
hose
has
continuous
slope.
Use
caution
with
hose
clamp,
be
sure
not
to
over
tighten
and
crack
drain
spud.
Note:
Do
not
sweat
or
directly
attach
metal
drain
line
to
fitting.
Do
not
use
solvent
type
adhesive
when
connecting
plastic
drain
hose,
since
damage
to
fitting
could
result.
5
install
a
collar
in
a
convenient
location
on
the
opposite
plenum.
Slip
on
a
90°
elbow
and
measure
the
length
of
6"
round
duct
required
to
make
the
connection.
The
duct
will
fit
into
the
round
collar
on
the
side
of
the
unit.
If
the
furnace
has central
air
conditioning,
add
a
duct
damper.
Assemble
components
with
sheet
metal
screws.
Support
bypass
ducts
in
excess
of
4
to
prevent
sagging.
8
Tap
into
a
water
supply
line
with
the
saddle
valve
furnished.
The
humid-
ifier
will
function
with
cold,
hot,
soft-
ened
or
unsoftened
water.
The
use
of
service
hot
water
(140°F
MAX.)
and
constant
blower
operation
will
pro-
vide
maximum
evaporative
capacities.
NOTE:
The
saddie
vaive
is
designed
to
be
fully
opened
or
closed.
Do
net
use
it
to
regulate
water
flow.
1 1
Open
saddle
valve
and
turn on
furnace.
Turn
up
Humidifier
Control
to
operate
unit.
Allow
unit
to
run
until
water
is
observed
coming
out
of
drain
line.
Check
to
see
if
unit
is
water
tight
and
all
electrical
components
function
properly.
Reset
Humidifier
Control
to
recommended
level.