Manual
I Installation Instructions R410-A Split System Condensers I
Installation/Startup Information
These instructions must be read and understood com-
pletely before attempting installation.
Installation or repairs made by unqualified
persons can result in hazards to you and others.
Installation MUST conform with local building
codes or, in the absence of local codes, with the
the National Electrical Code NFPA 70/ANSI
C1-1999 or current edition and Canadian
Electrical Code Part 1 CSA C.22.1.
The information contained in this manual is
intended for use by a qualified service technician
familiar with safety procedures and equipped
with the proper tools and test instruments.
Failure to carefully read and follow all instruc-
tions in this manual can result in equipment
malfunction, property damage, personal injury
and/or death.
After uncrating unit, inspect thoroughly for hidden damage.
If damage is found, notify the transportation company im-
mediately and file a concealed damage claim.
Figure 1 1 Dimensions
-- 24-3/4
Chassis #1
6-1/2
FRONT
36
33
Chassis #3
CAUTION
Improper installation, adjustment, alteration, service or
maintenance can void the warranty.
The weight of the condensing unit requires caution and
proper handling procedures when lifting or moving to avoid
personal injury. Use care to avoid contact with sharp or
pointed edges.
Safety Precautions
1. Always wear safety eye wear and work gloves when
installing equipment.
2. Never assume electrical power is disconnected. Check
with meter and disconnect.
3. Keep hands out of fan areas when power is connected
to equipment.
4. Refrigerant causes frost-bite burns.
5. Refrigerant is toxic when burned.
CAUTION
R410-A systems operate at higher pressures than
standard R-22 systems. Do not use R-22 service
equipment or components on Enviromax equipment.
NOTE TO INSTALLING DEALER: The Owners Instruc-
tions and Warranty are to be given to the owner or promi-
nently displayed near the indoor Furnace/Air Handler Unit.
FRONT
26 '
29-3/4 _
Chassis #2
T
32-3/4
Minimum Mounting Pad Sizes with pad starting at
9" from structure for minimum clearances
Chassis #1 20" W X 20" D
Chassis #2 24" W X 26" D
Chassis #3 27" W X 28" D
f
"H" = Unit Height
Refer to Specification Sheet
]
I
IIIIIIIIIIIIIIIIIIIIIIIIIIIIII
IIIIIIIIII IIIIIIIIII IIIIIIIIII q_T T_ ]q_
11/2
L1 1/2 38-11-17