Installation Instructions SPLIT SYSTEM 3 PHASE 6.
_ Installation Instructions Split System Condensers Installation/Startup Information These instructions must be read and understood completely before attempting installation. CAUTION Installation or repairs made by unqualified persons can result in hazards to you and others. Installation MUST conform with local building codes or, in the absence of local codes, with the the National Electrical Code NFPA 70/ANSI C1-1999 or current edition and Canadian Electrical Code Part 1 CSA C.22.1.
I Split System Condensers Installation Instructions Locating The Outdoor Unit: Check local codes covering zoning, noise, platforms. If practical, avoid locating next to fresh air intakes, vent or bedroom windows. Noise may carry into the openings and disturb people inside. Roof top installations are acceptable providing the roof will support the unit and provisions are made for water drainage and the noise or vibration through the structure.
Split System Condensers _ Installation Instructions Figure 2 I Clearances Recommended Clearances 24" Minimum Clearances 24" 24" 24" 24" 24" Minimum Minimum Clearances 6_ F Clearances , ! J 18" 18" 24" 24" J 18" Minimum Clearances 24" 24" 24" _J 24" 24" 501 01 1504 O0 I
I Split System Condensers Installation Instructions Installing Refrigerant Lines Component Matches Figure 3 Oil Traps Check to see that you have the proper system components. APPROVED MATCHED SYSTEM COMPONENTS MUST BE USED, Refer to the Sales Specification Sheet or Split System Summary for match data, orifice sizes, and recommended charge. 10" Max Mill. The suggessted charge values are for split systems using 25ft (7.5m) of refrigerant line between the indoor and outdoor units.
_ Installation Instructions Split System Condensers 3. Insert tubing into swage fitting connection. 4. Apply heat absorbing paste or heat sink product to prevent damage to the service valve. CAUTION Do not heat valve body above 250 degrees E 5. Braze joint. 6. Quench the joint and tubing with water using a wet rag. Leave rag on fitting body and re-wet with water to help cool area.
I Split System Condensers Installation Instructions I Figure 5 - Charging Chart UNIT CAC075 CAC090 CAC120 Reference Charge Level 1 R-22 Ounces 245 240 384 Liquid Line Size 2 5/8" (1/2") 5/8" (1/2") 5/8" Suction Line Size 3 1-1/8" 1-1/8" 1-1/8" Min. Subcooling Recommended Deg.
_ Installation Instructions Start-Up Start-up Split System Condensers Procedure Procedure Figure 1. Close electrical disconnects to energize system. 2. Energize crankcase heater on units so equipped. 3. Set Thermostat selector switch to OFF. 4. Set room thermostat at desired temperature. Be sure setpoint is below indoor ambient temperature for cooling and above indoor ambient for heating. 5.
I Split System Condensers Maintenance installation Instructions 1, Free air flow is essential, Keep the outdoor coil clean and free of restrictions. Keep fences, shrubs, snow drifts and any other obstructions at least two feet from all coil air inlets. Electrical Shock Hazard. 2. Shut off electric power at fuse box or service panel before making any electrical connections. Coils may require cleaning. The coil should always be cold when cleaning. Use an alkaline based cleaner only.
INTERNATIONAL LIMITED For Cooling SAVE THIS CERTIFICATE. province. COMFORT WARRANTY PRODUCTS CERTIFICATE & Heating Products It gives you specific legal rights, and you may also have other rights which may vary froln state to state and province to If your unit needs servicing, contact a qualified dealer or qualified service technician of your choice. When requesting service, please have the model and serial number from each unit in your heating and/or cooling system readily available.
ADDITIONAL TERMS FOR RESIDENTIAL APPLICATIONS ONLY The Additional Terms for the components listed below are in addition to, and subject to, the General Terms on the reverse side of this page. Warranty coverage is limited to parts that fail due to defect in materials or workmanship during the specified term. CENTRAL GAS & OIL FURNACE HEAT EXCHANGERS* Gas Model Series: C9MPV. H9MPV. T9MPV. C9MPT. H9MPT. T9MPT, C9MPD. H9MPD. T9MPD: Limited Lifetime Warranty on heat exchangers.