Installation guide
Circulation Air Blower Data (CFM #)
*8DNLO50B12 *8DNLIOOF14
Air Delivery in Cubic Feet per Minute (C.F.M.)
(Furnace Rated @0.5" WC ESP)
TAP LOW MED L MED H HIGH
_-_5, .10 702 963 1260 1537
,£ ,30 624 845 1183 1416
No
_ .60 510 760 1088 1308
=u ,70 412 617 917 1111
•_ .90 310 468 664 948
uJ
1,00 249 436 529 808
*8DNLO75B12
Air Delivery in Cubic Feet per Minute (C.F.M,)
(Furnace Rated @0.5" WC ESP)
TAP LOW MED L MED H HIGH
•_O' ,10 634 728 975 1353
'£ .30 533 653 936 1307
_o
_ ,50 454 559 861 1225
=u .70 373 473 737 1087
"_ ,90 255 392 605 884
ua
1,00 232 294 529 764
*8DNL075F16
Air Delivery in Cubic Feet per Minute (C.F.M.)
(Furnace Rated @0.5" WC ESP)
= TAP LOW MED L MED H HIGH
5 .10 648 900 1285 1789
,£ ,30 628 916 1328 1747
_ .50 611 889 1309 1680
=u ,70 557 843 1240 1588
.90 485 748 1122 1452
x
_J
1,00 441 680 1041 1374
• Denotes Brand
Air Delivery in Cubic Feet per Minute (C.F.M.)
(Furnace Rated @0.5" WC ESP)
TAP LOW MED L MED H HIGH
_-_5, .10 756 1012 1372 1881
,£ ,30 585 888 1273 1724
No
_ .50 491 780 1176 1606
=u ,70 387 697 1035 1481
x .90 255 561 873 1281
uJ
1.0 210 444 767 1132
*8DNL100L20
Air Delivery in Cubic Feet per Minute (C.F.M,)
(Furnace Rated @0.5" WC ESP)
TAP LOW MED L MED H HIGH
•_ O' ,10 1798 2024 2212 2375
'-£ .30 1709 1896 2081 2205
To
_ ,50 1614 1774 1922 2026
=u .70 1470 1614 1752 1860
x ,90 1282 1428 1548 1645
uJ
1.00 1065 1263 1407 1508
*8DNL125L20
Air Delivery in Cubic Feet per Minute (C.F.M.)
(Furnace Rated @0.5" WC ESP)
= TAP LOW MED L MED H HIGH
5 .10 1936 2165 2319 ---
,£ ,30 1845 2028 2246 2334
_ .50 1728 1902 2061 2172
=u ,70 1536 1695 1856 1952
.90 1331 1490 1800 1687
x
_J
1.00 1215 1352 1424 1537
I # CFM - Cubic feet per minute airflow.
Filter required for each return-air inlet. Airflow performance includes 1" washable (600 FPM max) filter media.
44101231402 THIS DATA IS SUBJECT TO CHANGE WITHOUT NOTICE [_