Instructions

INSTRUCTIONS
SEPARATION KIT
RMK-2
Thank you for purchasing the RMK-2
SEPARATION KIT
.
The RMK-2 allows you to install the IC-F1700 series
transceiver front panel separately from the main unit
for added installation convenience and operation.
Use either the optional OPC-607, OPC-608 or OPC-
609
SEPARATION CABLE
with the RMK-2.
Separation
The optional OPC-607
(3 m; 9.84 ft), OPC-608 (8 m; 26.3 ft) or
OPC-609* (1.9 m; 6.3 ft)
SEPARATION CABLE
is required for in-
stalling the transceiver front panel and main unit separately.
*For Europe version, only the OPC-609 is available.
q Turn the transceivers power OFF, then disconnect the DC
power cable.
w Unscrew the 4 bottom screws, then remove the bottom
cover from the transceiver in the direction of the arrow.
e Disconnect the flat cable and speaker cable* from the
main unit.
r Unscrew the 2 side screws, then remove the front panel
from the transceiver main unit in the direction of the arrow.
t Unscrew the 4 screws, then remove the rear plates from
both the front panel and main unit attachments.
Continue to the back page.
Rear plate
*This illustration shows
the description for the
front panel attachment.
Unscrew the cir-
cuit board screw.
Main unit
Front panel
Flat cable
Speaker cable*
*Depending on version
Bottom cover
CAUTION! To avoid damage to the transceiver, turn the
power OFF before separating from the main unit.
Supplied accessories
Main unit attachment
Front panel attachment and bolts (M3×15)
Flat cable
Mounting bracket
Flat washers
(M5)
Spring washers
(M5)
Mounting screws
(M5×12)
Self-tapping screws
(M5×16)
Bracket screws
Nuts (M5)
Icom, Icom Inc. and the logo are registered trademarks of Icom Incor-