Operation Manual
New2001
37
12
TROUBLESHOOTING
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
PROBLEM POSSIBLE CAUSE SOLUTION REF.
The transceiver does not
turn ON.
• The battery is depleted.
• Bad connection to the battery pack.
• Recharge the battery pack.
• Check the connection to the transceiver.
pp. 33,
34
p. 3
No sound from the speak-
er.
• Squelch level is too tight.
• Volume level is too low.
• Speaker has been exposed to water.
• Water has entered to [SP MIC] connector.
• Set squelch to the threshold point.
• Rotate [VOL] to set a suitable level.
• Hold down [F] to drain water from the speaker.
• Dry [SP MIC] connector.
p. 13
p. 11
p. 13
—
Transmitting is impossible,
or high power can not be
selected.
• Some channels are for low power or receive
only.
• The battery is exhausted.
• The battery is overcharged.
• The output power is set to low.
• The transceiver is over heated.
• Change channels.
• Recharge the battery pack.
• Verify the battery voltage is correct.
• Push [H/L•LOCK] to select high power.
• Turn OFF the power, leave it at room temperature for
a while.
pp. 11,
12,
40–42
pp. 33,
34
—
p. 11
—
The displayed channel
cannot be changed.
• Lock function is activated. • Push [H/L•LOCK] for 1 second to cancel the function. p. 12
Scan does not start. •
Favorite (TAG) channels are not programmed.
• Set the desired channels as “Favorite (TAG)” channels. p. 15
No beeps. • Beep tones are turned OFF. • Set the beep tones to ON (Fix Beep/Preset) in the SET
mode.
p. 26
Does not record or does
not record properly.
• The read/write capacity has been exceeded
(the recording counter displays 100 or more.
(p. 4)), or the memory is damaged.
• The memory IC should be replaced.
Ask your technical dealer for service.
—
The weak signal is not
recorded by the automatic
recording function.
• The automatic recording threshold level is
too deep.
• Set the automatic recording threshold level to shallow. p. 30
“CHARGE” comment
blinks
• The connected battery is depleted. • Recharge the battery pack. pp. 33,
34