User Guide

114
12 OTHER FUNCTIONS
Power save
The power save function reduces the current drain to con-
serve battery power.
The power save duty cycle, the ratio of receive circuit on to
receive circuit off during standby, can be set to automatic
(de-
fault), 1 : 1 (150 msec. : 150msec.), 1 : 4 (150 msec. : 600msec.), 1
: 8
(150 msec. : 1200msec.) or OFF with POWER SAVE in set
mode.
(p. 88)
•“AUTO selects 1:1 duty ratio when receiving no signal for 5 sec.,
then 1:4 60 sec. after that.
The ratio becomes 1:8 when no signal
is received for another 60 sec.
Auto power OFF
The transceiver can be set to automatically turn OFF after a
specied period with a beep when no switch is pushed.
120 min., 90 min., 60 min., 30 min. and OFF can be speci-
fied. The specified period is retained even when the trans-
ceiver is turned OFF by the auto power-off function. To cancel
the function, select OFF in the auto power-off item in set
mode.
This can be selected with AP OFF in set mode.
(p. 88)
Auto power ON
The transceiver can be set to automatically turn ON after a
specied period. The timer can be selected within 30 min. to
24 hrs. in 30 min. steps.
This can be selected with AP ON in set mode.
(p. 89)
When operating with battery pack or case and the battery
is exhausted, auto power-on does not function.
A slight current still ows in the circuits during standby con-
dition of the auto power-on function.
MENU screen SET MODE AP ON
(Push [MENU/LOCK]) (Rotate [DIAL]
, then push [ï](5)
.)
MENU screen
SET MODE
AP OFF
(Push [MENU/LOCK]) (Rotate [DIAL]
, then push [ï](5)
.)
150 msec.
150 msec.
60 sec.
60 sec.
600 msec.
1200 msec.
No signal
5 sec.
Circuit ON
Circuit OFF
∼
∼
∼
∼
MENU screen
SET MODE
POWER SAVE
(Push [MENU/LOCK]) (Rotate [DIAL]
, then push [ï](5)
.)