If your transceiver seems to be malfunctioning, please check the following points before sending it to a service center.
PROBLEM POSSIBLE CAUSE SOLUTION REF.
No power comes on. The battery is exhausted. Recharge the battery pack.
pgs. 2527
Bad connection for the battery pack. Check the connection to the transceiver. p. 7
The CP-20s fuse is blown. Check for the cause, then replace the p. 29
CP-20s fuse to new one.
No sound comes from Squelch level is too deep. Set squelch to the threshold point. p. 8
the speaker. Volume level is too low. Set [VOL] to a suitable level. p. 9
Transmitting impossible. WX channels or NAV band is selected. Set COM band in frequency mode. p. 8
The battery is exhausted. Recharge the battery pack.
pgs. 2527
Operating frequency or Lock function is activated. Push , then push [7 ]. p. 11
memory channel can not
be changed.
Scan does not start. All memory channels in the selected bank Set the TAG settings of desired p. 17
are not programmed as TAG channels. channels.
Squelch is open. Set the squelch level to tighten. p. 8
There is not more than 2 memorized Program 2 or more memory channels. p. 16
channels.
No beep sounds. Beep tones turned OFF. Push , then push [8
BEEP], and p. 11
rotate [DIAL] to adjust the beep tone
level.
Fuse 8 A
D CP-20 fuse replacement
If the fuse blows or the receiver stops functioning while
operating with the optional CP-20
CIGARETTE LIGHTER CABLE
,
find the source of the problem if possible, and replace the
damaged fuse with a new rated one (FGB 8 A) as shown
right.