IC-400PRO.qxd 03.6.
IC-400PRO.qxd 03.6.19 6:13 PM Page i (1,1) IMPORTANT PRECAUTION READ ALL INSTRUCTIONS carefully and com- RWARNING! NEVER connect the transceiver to an AC outlet. This may pose a fire hazard or result in an electric shock. pletely before using the transceiver. SAVE THIS INSTRUCTION MANUAL — This instruction manual contains important operating instructions for the IC-400PRO UHF TRANSCEIVER. EXPLICIT DEFINITIONS WORD DEFINITION Personal injury, fire hazard or electric shock RWARNING may occur.
IC-400PRO.qxd 03.6.19 6:13 PM Page ii (1,1) DO NOT push the PTT when not actually desiring to trans- BE CAREFUL! The transceiver will become hot when mit. operating continuously for long periods. DO NOT use or place the transceiver in areas with temperatures below –10°C or above +60°C, or in areas subject to direct sunlight, such as the dashboard. This device complies with Standard Australia Specification No. AS/NZS43651996 and AS4295-1995.
IC-400PRO.qxd 03.6.19 6:13 PM Page iii (1,1) TABLE OF CONTENTS IMPORTANT ........................................................................ i EXPLICIT DEFINITIONS ..................................................... i PRECAUTION ..................................................................... i TABLE OF CONTENTS ...................................................... iii SUPPLIED ACCESSORIES ............................................... iv 1 PANEL DESCRIPTION ................................
IC-400PRO.qxd 03.6.19 6:13 PM Page iv (1,1) SUPPLIED ACCESSORIES q Microphone .................................................................. 1 q w e w Microphone hanger and screw set .......................... 1 set e Microphone hanger cable .............................................. 1 IC OM r DC power cable (OPC-1194) ..........................................1 t Function name stickers* (KEY STICKER) ......................1 y Mounting bracket ...............................................
IC-400PRO.qxd 03.6.19 6:13 PM 1 Page 1 (1,1) PANEL DESCRIPTION ■ Front panel q i w Function Display (p. 4) u y t q AF VOLUME CONTROL KNOB Rotate the knob to adjust the audio output level. • Minimum audio level is pre-programmed. w [ ]/[ ] KEYS* ➥ Push to select an operating channel. ➥ After pushing [O], push to toggle between CB bank and Private bank (user programmable channels). r e Speaker r [O] KEY* ➥ Push to enter channel bank selection mode.
IC-400PRO.qxd 03.6.19 6:13 PM Page 2 (1,1) PANEL DESCRIPTION 1 t [DUP] KEY* ➥N Push to toggle the transmit frequency mode between duplex and simplex. (CB channel 1 to 8 only) u [MONI] KEY* ➥N Activates the following functions on each channel independently: • Duplex: The set TX frequency is used for the transmission. • Simplex: The set RX frequency is used for the transmission. • Push and hold the key to release the mute to the channel (audio is emitted; ‘Audible’ condition). -“ ” appears.
IC-400PRO.qxd 03.6.19 6:13 PM 1 Page 3 (1,1) PANEL DESCRIPTION Key flow chart for the default setting Push [ ] to turn power ON. Normal mode : [CH Up] : [Scan Start/Stop] : [CH Down] : [Moni(Audi)] : [Dup/Pri] : [Bank/Func] Push [O] for 1 sec. Function mode : [CH Up] : [ID-MR Select] : [CH Down] : [Call] : [CONT/SGL] : [Bank/Func] Push [O] for 1 sec. Set mode / : Set the desired level/mode. : Change the individual setting. : Change the common setting. : Turn the function ON and OFF.
IC-400PRO.qxd 03.6.19 6:13 PM Page 4 (1,1) PANEL DESCRIPTION 1 ■ Function display q w e r t y 1 u u SCRAMBLER INDICATOR Appears when the scrambler function is activated. (Optional UT-109 (#02)/UT-110 (#02) SCRAMBLER UNIT is required.) i o !0 !1 q TRANSMIT INDICATOR Appears while transmitting. w BUSY INDICATOR Appears while receiving a signal or when the squelch is open. e SIGNAL STRENGTH METER Indicates relative receive signal strength level.
IC-400PRO.qxd 03.6.19 6:13 PM 2 Page 5 (1,1) BASIC OPERATION ■ Turning power ON ■ Channel selection ➥ Push [ ➥ Push [ ] to turn the power ON. ]/[ ] to select the desired operating channel. • While pushing and holding [ ] or [ ], the displayed channel changes continuously until channel number “01” appears. • When displayed channel stops at channel number “01”, beeps are emitted.
IC-400PRO.qxd 03.6.19 6:13 PM Page 6 (1,1) BASIC OPERATION 2 ■ Receiving and transmitting RECEIVING: q Push [ ] to turn the power ON. w Select the desired operating channel. (p. 5) e While receiving a signal, adjust the audio output level to a comfortable listening level. TRANSMITTING: q While pushing and holding [PTT], speak into the microphone at your normal voice level. w Release [PTT] to receive.
IC-400PRO.qxd 03.6.19 6:13 PM 3 Page 7 (1,1) REPEATER OPERATION ■ Repeater operation ■ Accessing a repeater Repeaters allow you to extend the operational range of your radio. A repeater amplifies received signals and re-transmits them on a different channel, allowing you to communicate over greater distances with improved reliability. When using a repeater, the transmit channel is shifted from the receive channel by 30 channels.
IC-400PRO.qxd 03.6.19 6:13 PM Page 8 (1,1) 4 SCAN OPERATION ■ Scan types The transceiver has 4 scan types, tag function and 4 resume conditions providing scanning versatility. Tag channels are independently set for open, group and priority scans. Initially, all channels may be set as tag channels for all scans. IMPORTANT!: A microphone should be on hook to start scanning.
IC-400PRO.qxd 03.6.19 6:13 PM 4 Page 9 (1,1) SCAN OPERATION ■ Scanning preparation IC-400PRO scans all tagged channels, and can be selected so the scan resume condition is a pause or timer scan. Therefore, these items must be set before starting a scan (except the repeater search scan). These items must be set for each scan type (open, group and priority) independently. r Push [SCN] (Scan Start/Stop) to select the tag setting ON and OFF.
IC-400PRO.qxd 03.6.19 6:13 PM Page 10 (1,1) SCAN OPERATION D Setting scan resume condition q Push [O] (Bank/Func) for 1 sec. to enter Function mode. w Push [O] (Bank/Func) for 1 sec. again to enter Set mode. [ t Push [ tion. - “T-5” - “T-10” - “T-15” - “P-5” Push [O] for 1 sec. Bank* 4 ]/[ ] to select the desired scan resume condi- : Scan pauses for 5 sec. then resumes. : Scan pauses for 10 sec. then resumes. : Scan pauses for 15 sec. then resumes.
IC-400PRO.qxd 03.6.19 6:13 PM 4 Page 11 (1,1) SCAN OPERATION ■ Open scan Open scan searches for being transmitted signals automatically and makes it easier to locate new stations for contact or listening purposes. IMPORTANT!: • A microphone should be on hook to start scanning. • During open scan, transmission is inhibited except on a busy channel. q Push [SCN] (Scan Start/Stop) for 1 sec. to enter the scan type selection mode. Previously selected scan type is displayed. Push [SCN] for 1 sec.
IC-400PRO.qxd 03.6.19 6:13 PM Page 12 (1,1) SCAN OPERATION 4 ■ Group and priority scans Group and priority scans repeatedly watch a priority channel while scanning specified channels. This is useful when waiting for a call on the priority channel or several specified channels. Group and priority scans behave differently when transmitting. Group scan can only transmit on a busy channel, and priority scan can only transmit on a priority channel or start channel. r Select the priority channel if desired.
IC-400PRO.qxd 03.6.19 6:13 PM 4 Page 13 (1,1) SCAN OPERATION ■ Repeater search scan The repeater search scan is not only searching for a signal on the repeater channels, but also access a repeater by transmitting automatically in sequence. Thus the repeater search scan function searches an available repeater in the area even if the repeater is not in use. IMPORTANT!: A microphone should be on hook to start scanning. The repeater search scan detects a signal on the repeater output, CH 1 to 8, only.
IC-400PRO.qxd 03.6.19 6:13 PM Page 14 (1,1) SCAN OPERATION 4 D Repeater search scan flow Scanning channel is displayed. 4 Scan Searches for signal on repeater output signal. Access to the repeater automatically. Wait for a signal from the repeater. When not reply signal is received. Access to the next repeater automatically. Scan is cancelled automatically.
IC-400PRO.qxd 03.6.19 6:13 PM 5 Page 15 (1,1) GROUP MODE OPERATION ■ Group mode (CTCSS) [ D Setting the CTCSS frequency The IC-400PRO is equipped with 51 CTCSS frequencies for group mode operation. The group mode operation provides communication with silent stand-by since you will only receive calls from group members using the same CTCSS frequency. First of all, set the same CTCSS frequency for all group member’s transceivers.
IC-400PRO.qxd 03.6.19 6:13 PM Page 16 (1,1) GROUP MODE OPERATION 5 To cancel the group mode operation: q While in Function mode, push [O] (Bank/Func) for 1 sec. to enter Set mode. ✔ What is CTCSS (Continuous Tone Coded Squelch System) GROUP MODE ? • Push [O] (Bank/Func) for 1 sec. to enter the transceiver into Function mode. CTCSS (Continuous Tone Coded Squelch System) GROUP MODE allows communication with silent stand by. Only signals containing a specific CTCSS frequency can open the squelch.
IC-400PRO.qxd 03.6.19 6:13 PM 6 Page 17 (1,1) SELCALL OPERATION ■ General ■ Calling operation In addition to the group mode operation for silent stand-by, the SelCall operation is available. SelCall is an abbreviation for “Selective Calling”. In Group mode operation, there are 51 ways to make an individual call with CTCSS frequencies versus 100,000 ways to make an individual call with Selcall using 5tone. SelCall allows you to selectively call another unit that is operating on the same channel.
IC-400PRO.qxd 03.6.19 6:13 PM Page 18 (1,1) SELCALL OPERATION e Push [MONI] (Call) to set the TX code channel, and return to Function mode. Push [MONI] r Push [MONI] (Call) to transmit the code on the selected channel. Appears while transmitting Push [MONI] ✔ CONVENIENT! • The TX code channel name can be assigned to the all 32 TX code channel via the optional CS-400PRO CLONING SOFTWARE. The TX code channel name allows you to easy to select the channel, find the channel user, and so on.
IC-400PRO.qxd 03.6.19 6:13 PM 6 Page 19 (1,1) SELCALL OPERATION r Push [ ]/[ ] to set the desired code. • Select “❋” when group code is set. Push [ ] or [ o Push [MONI] (Call) to transmit the code on the selected channel. Appears while transmitting ] Push [MONI] t Push [MONI] (Call) to set the code and the editable digit move to right automatically. Push [MONI] y Repeat step r and t to input all allowed digits. u Push [MONI] (Call) to set the TX code.
IC-400PRO.qxd 03.6.19 6:13 PM Page 20 (1,1) SELCALL OPERATION 6 ■ When receiving a call D Receiving an individual call D Receiving a group call When receiving an individual call (default setting); When receiving a group call (default setting); - “PiRo” beeps sound repeatedly for 10 sec. - Transmits the answer back call with single tone for 2 sec. - The received ID code is displayed and memorised into the transceiver.
IC-400PRO.qxd 03.6.19 6:13 PM 6 Page 21 (1,1) SELCALL OPERATION ■ Setting the silent stand-by condition The SelCall mute condition allows silent operation until you are selcalled. q While in Function mode, push [DUP] (CONT/SGL) and select the single tone to activate the SelCall mute (‘Inaudible’ condition). • Push [O] (Bank/Func) for 1 sec. to enter the transceiver into Function mode. • When the single tone is selected, “SGL” is displayed briefly, and the under bar appears as below.
IC-400PRO.qxd 03.6.19 6:13 PM Page 22 (1,1) OTHER FUNCTIONS ■ Smart-Ring and ATS (Automatic Transponder System) These functions have an answer back feature, and allows you to confirmation of whether or not a call has reached the receiving party even if the operator is temporarily away from the transceiver. The Smart-Ring is for manual, and the ATS is for automatic confirmation. Both functions are compatible with the IC-40Jr and IC-4088S.
IC-400PRO.qxd 03.6.19 6:13 PM 7 Page 23 (1,1) OTHER FUNCTIONS ■ Voice scrambler function (optional UT-109/110 is required) The voice scrambler function provides communication privacy. The optional UT-109/110 (#02) VOICE SCRAMBLER UNITS provides high performance private communication between stations with the same scrambling codes. The scrambler is not compatible with the IC-4088S’s scrambler system.
IC-400PRO.qxd 03.6.19 6:13 PM Page 24 (1,1) OTHER FUNCTIONS ■ DTMF transmission KEY ASSIGNMENT Up to 8 DTMF (Dual Tone Multiple Frequency) code channels are available for storage of often used DTMF codes of up to 24 digits and the automatic DTMF transmission function is available without using the optional HM-100TN DTMF MICROPHONE. DTMF signaling can be used for remote control via phone patch system, etc.
IC-400PRO.qxd 03.6.19 6:13 PM 7 Page 25 (1,1) OTHER FUNCTIONS ■ RX frequency setting (for private banks only) The receive frequency in the private bank channels can be re-programmed within 450 to 500 MHz frequency range depending on the setting. q Push [ ]/[ ] to select the desired channel. w While in Function mode, push [O] (Bank/Func) for 1 sec. to enter Set mode. • Push [O] (Bank/Func) for 1 sec. to enter the transceiver into Function mode.
IC-400PRO.qxd 03.6.19 6:13 PM Page 26 (1,1) OTHER FUNCTIONS i Push [DUP] to set the number and the editable digit move to right. Push [DUP] o Repeat step u and i to input the desired frequency. !0 Push [DUP] to set the RX frequency. ■ Wide/Narrow function 7 KEY ASSIGNMENT This function temporarily changes the bandwidth between wide or narrow on Private channels only. [Wide/Narrow] must be assigned to the desired programmable key using the optional CS-400PRO CLONING SOFTWARE.
IC-400PRO.qxd 03.6.19 6:13 PM 7 Page 27 (1,1) OTHER FUNCTIONS ■ Set mode Set mode allows you to change seldom used common setting for the transceiver, or individual setting for the operating channel. In this case you can “customize” transceiver operation to suit your preferences and operating style. To enter the common setting for the transceiver, or individual setting, push the appropriate key in step t below. Entering the Set mode: q Push [O] (Bank/Func) to enter the channel bank selection mode.
03.6.19 6:13 PM Page 28 (1,1) OTHER FUNCTIONS 7 D Set mode flow chart The following flow chart describes Set mode details. ❍ Common setting AF Min level Normal mode Push [O] (Bank/Func) for 1 sec. Lockout Auto power OFF Squelch level Scan Stop Timer SelCall Form Function mode 7 Set mode Push [SCN] for 1 sec. Push [O] (Bank/Func) for 1 sec. Push [MONI] for 1 sec. IC-400PRO.
IC-400PRO.qxd 03.6.19 6:13 PM 7 Page 29 (1,1) OTHER FUNCTIONS D Common setting • Squelch level Adjust the noise squelch level within a 0 to 255 range. • Backlight condition The transceiver has display backlight for night-time operation. Select the desired condition. - OFF : Backlight never lights. - DIM : Backlight lights dimly.
IC-400PRO.qxd 03.6.19 6:13 PM Page 30 (1,1) OTHER FUNCTIONS 7 • Lockout CB Select the transmission lockout (temporary transmission inhibit) capability from OFF, Busy and Rpt 1 for CB mode. • SelCall Format Select the SelCall format from CCIR, ZVEI1, ZVEI2, DZVEI, EEA, EEA2, DAPL, TP40, TP100, DTMF, IC20 and INH. - OFF: No restriction for receiving a signal. - BUSY (Busy Lockout): Transmission is inhibited while receiving a signal.
IC-400PRO.qxd 03.6.19 6:13 PM 7 Page 31 (1,1) OTHER FUNCTIONS • STN code (Station to be called) ➥ Select the station code channel with [ ]/[ ] key. ➥ Set the desired station code following the steps as below. q While the station code is displayed, push [DUP] to enter the station code edit mode. w Push [DUP] to select the desired digit to be edited. • Editable digit blinks e Push [ ]/[ ] to set the desired code. • Select “❋” when group code is set.
IC-400PRO.qxd 03.6.19 6:13 PM Page 32 (1,1) OTHER FUNCTIONS D Individual setting 7 • Scrambler function (The optional UT-109/110 is required) Set the scrambler codes to provides high performance private communication between stations with the same codes. ACA class licence inhibits using this function in channels 5, 11 and 35, or while accessing a repeater. (p. 23) • CTCSS function Select CTCSS frequency.
IC-400PRO.qxd 03.6.19 6:13 PM 7 Page 33 (1,1) OTHER FUNCTIONS • RX frequency The receive frequency can be re-programmed from the transceiver if permitted. (p. 25) q While the receive frequency is displayed, push [DUP] to enter the RX frequency setting mode. w Push [DUP] to select the digit to be edited. e Push [ ]/[ ] to set the desired number. r Push [DUP] to set the number and the editable digit move to right. t Repeat step e and r to input the desired frequency. y Push [DUP] to set the RX frequency.
IC-400PRO.qxd 03.6.19 6:13 PM Page 34 (1,1) PROGRAMMABLE FUNCTION KEYS The following functions can be assigned to [MONI], [SCN], [DUP], [O], [ ] and [ ] programmable function keys with the optional CS-400PRO CLONING SOFTWARE. In the following explanations, programmable function names are bracketed. The specific switch used to activate the function depends on programming. 8 SCAN START/STOP KEY ➥ Push to start or stop the scan. ➥ Push and hold to enter the scan type selection mode.
IC-400PRO.qxd 03.6.19 6:13 PM 8 Page 35 (1,1) PROGRAMMABLE FUNCTION KEYS MONITOR KEY Activates one of (or two of) the following functions on each channel independently: • Push and hold the key to unmute the channel (audio is emitted; ‘Audible’ condition). • Push the key to toggle between the mute and unmute conditions (toggles between ‘Audible’ and ‘Inaudible’). • Push the key to mute the channel (sets to ‘Inaudible’ only). • Push the key to unmute the channel (sets to ‘Audible’ only).
IC-400PRO.qxd 03.6.19 6:13 PM Page 36 (1,1) PROGRAMMABLE FUNCTION KEYS 8 DUP/PRI KEY ➥ Push to toggle the transmit frequency mode between duplex and simplex. • Duplex: The set TX frequency is used for the transmission. • Simplex: The set RX frequency is used for the transmission. ➥ Push for 1 sec. to set the selected channel to priority or normal. ➥ Priority channel is used for group or priority scan. CONT/SGL KEY Push to toggle the 5tone mute activity CONT (Continuous Tone) and SGL (Single Tone).
IC-400PRO.qxd 03.6.19 6:13 PM 9 Page 37 (1,1) CONNECTION AND MAINTENANCE ■ Rear panel and connection w IMPORTANT! The microphone hanger connection is necessary to use the scanning function. Optional speaker (SP-22) Antenna q red: + t 12V Battery Optional cable (OPC-617) e r 37 black: NEVER connect to a 24 V battery. R C A U T I O N ! N E V E R r emove the fuse-holder from the DC power cable. NOTE: Use the terminals as shown below for the cable connections.
IC-400PRO.qxd 03.6.19 6:13 PM Page 38 (1,1) CONNECTION AND MAINTENANCE 9 ■ Mounting the transceiver q ANTENNA CONNECTOR Connects to an antenna. Contact your dealer about antenna selection and placement. w MICROPHONE HANGER Connect the supplied microphone hanger to the vehicle’s ground for microphone on/off hook functions. (See p. 3) IMPORTANT!: The microphone hanger connection is necessary to use the scanning function. Scan starts when a microphone on hook.
IC-400PRO.qxd 03.6.19 6:13 PM 9 Page 39 (1,1) CONNECTION AND MAINTENANCE ■ Optional UT-108 installation Install the optional UT-108 unit as follows: q Turn the power OFF, then disconnect the DC power cable. w Unscrew the 4 cover screws, then remove the bottom cover. e Install the unit as shown in the diagram below. r Replace the bottom cover and screws, then re-connect the DC power cable.
IC-400PRO.qxd 03.6.19 6:13 PM Page 40 (1,1) CONNECTION AND MAINTENANCE 9 ■ Optional OPC-617 installation ■ Antenna Install the OPC-617 as shown below. A key element in the performance of any communication system is an antenna. Contact your dealer about antennas and the best places to mount them. ■ Fuse replacement A fuse is installed in the supplied DC power cable.
IC-400PRO.qxd 03.6.19 6:13 PM 10 Page 41 (1,1) SPECIFICATIONS D GENERAL D TRANSMITTER • Frequency coverage CB Private • Mode CB Private • Number of channels CB Private • Channel spacing CB Private • Current drain (approx.) TX RX • Output power (at 13.8 V DC) : 5 W • Modulation system : Variable reactance frequency modulation • Max.
IC-400PRO.qxd 03.6.19 6:13 PM Page 42 (1,1) OPTIONS UT-108 DTMF DECODER UNIT Provides pager and code squelch capabilities. UT-109/UT-110 VOICE SCRAMBLER UNITS • UT-109: Non-rolling type (max. 32 codes) • UT-110: Rolling type (max. 1020 codes) 11 SM-25 DESKTOP MICROPHONE For base station operation. Monitor switch is equipped. OPC-617 ACC CABLE UT-108 UT-109 UT-110 SP-22 EXTERNAL SPEAKER Compact and easy-to-install. Same as that supplied with some versions. Input impedance: 4 Ω Max.
IC-400PRO.qxd 03.6.19 6:13 PM A-6287D-1AU Printed in Japan © 2003 Icom Inc.