User Guide

• WRONG
Audio mute function (page 21)
Push [FUNC] then [
SQLY D(MUTE)] to mute
audio signals.
• Both the left and right bands S/RF meter blink in full-
scale condition.
Push [CLR A(MW)] (or any other key) to cancel the
function.
Programming a call channel
(page 39)
Operating frequency, duplex information, subaudible tone
information (tone encoder or tone squelch ON/OFF and its
frequency) and alphanumeric channel names can also be
programmed into the call channel.
• CORRECT
Audio mute function (page 21)
Push [FUNC] then [
SQLY D(MUTE)] to mute
audio signals.
The memory channel number indicator shows the
current condition and “Si” indications alternately.
Push [CLR A(MW)] (or any other key) to cancel the
function.
Programming a call channel
(page 39)
Operating frequency, duplex information, subaudible tone
information (tone encoder or tone squelch ON/OFF and its
frequency) can be programmed into the call channel.
BUSY
MAIN
T X
MAIN
T X
M
M
Shows the current condition and Si indication alternately.
MUTE
BUSY
MAIN
T X
MAIN
T X
M
M
S/RF meter blinks (full-scale).
MUTE
Erratum for IC-2720H
Please note the following correction in the IC-2720H instruction manual page 21, Audio mute func-
tion, and page 39, Programming a call channel.
A-6124D-2EX
IC-2720H_Errata.qxd 02.11.2 17:09 Page 1 (1,1)

Summary of content (1 pages)