Product Overview

Application Assistance
800.365.5525
visit us at: www.icmcontrols.com
Phone
315.233.5266
Fax
315.233.5276
LIS161
ICM855 and ICM856
HARD START CAPACITORS
All features and specications subject to change without notice.
Increases
Compressor
Starting
Torque
Up To
500%
Features
Positive Temperature Coefficient technology (PTC)
For PSC units with existing run capacitor only
OEM approved
Quick recycling
Self-adjusting to voltage fluctuation
Easy to install, 2 wires, clips, or screws
Boosts starting torque
Most economical
Capacitor:
– 1/2 to 10 HP
– 115 to 288 VAC
– 22 Amps Maximum
Wiring Diagram
Connect the two wires from the ICM855/856 in
parallel with the run capacitor (one wire each side)
without removing any original wires.
Use special “Piggy Back” terminal of the ICM855/856
if all of the run capacitor terminals are being used.
NOTE:
Install only on PSC
units equipped with run
capacitor
Applications
Low voltage situations
Tight or hard starting compressors
Use on any single phase A/C and refrigeration unit.
Models
Part # VAC
Increase
in Torque
Recommended
Range
ICM855 115-288 300% 1/2 to 10 HP
ICM856 115-288 500% 1/2 to 10 HP
Other ICM Motor Starting Devices
RapidStart
®
Series Devices
Voltage Sensing Models
– ICM850
– ICM860
Current Sensing Models
– ICM803 -
Ideally suited for 1/2 thru 3 HP
– ICM805 -
Ideally suited for 2 thru 5 HP
– ICM810 -
Ideally suited for 3 1/2 thru 10 HP

Summary of content (1 pages)