Product Overview
ICM295 & ICM296
SPARK IGNITION CONTROL MODULES
LIS230
Low cost, form, fit and functional replacement ignition control
• For use with intermittent pilot boilers, furnaces or other heating appliances
• Microprocessor-based precision
• Compatible with LP or Natural Gas
Features
ICM295
• Continuous spark until pilot flame
established
• Replaces Carrier LH33WZ510 and
comparable ignition controls
ICM296
• 100% safety lockout
• Replaces Carrier LH33WZ512 and
comparable ignition controls requiring 100%
safety lockout
ICM295 Specifications ICM296 Specifications
Control Voltage: Line 24 VAC (18-30 VAC) @ 50/60Hz
Prepurge: 0 or 10 seconds (system dependent)
Retries: Continuous
Operating Temperature: -40°F (-40°C) to 75°C (176°F)
Relative Humidity: 0% to 95% non-condensing
Spark Frequency: 15Hz for 90 seconds, 10Hz thereafter
Control Voltage: Line 24 VAC (18-30 VAC) @ 50/60Hz
Prepurge: None
Lockout: 5-6 minutes
Retries: None
Operating Temp.: -40°F (-40°C) to 75°C (176°F)
Relative Humidity: 0% to 95% non-condensing
Relay Contact Rating: 1 amp @ 24 VAC
Trail for Ignition: 90 seconds
Flame Failure Response Time: 0.8 sec. max.
Spark Frequency: 60 Hz