Product Overview

ICM292
GAS IGNITION CONTROL BOARD
LIS223-1
Replaces
Rheem: 62-24140-04
Features
Direct Spark Ignition (DSI) control
board
Microprocessor-based
Controls inducer motors, air cleaner
(if equipped), humidifier (if equipped),
spark ignitor and the gas valve
Monitors timing, trial for ignition,
system switches, flame sensing and
lockout
100% lockout safety feature
Compatible with LP or Natural Gas
LED indication for status and fault
codes to aid in troubleshooting
Specifications
Control voltage: 24 VAC (18-30 VAC), 60 Hz
Line voltage: 115 VAC, 60 Hz
Power consumption: 0.3A plus gas valve current at 24 VAC
Operating temperature: -40°C (-40°F) to 75°C (176°F)
Timing
Pre-purge: 30 seconds
Trial for ignition: 7 seconds
Retries: Two groups of two, 30 seconds delay within the
group and 3 minutes delay between groups
Lockout: 1 hour
Post-purge: 90, 120, 160 and 180 seconds
Inputs
Power: 24 VAC and COM
Thermostat interface: R, W, Y and G
System switches: Vent Pressure and Limit switches
(Main and Over-temperature switches in series)
Flame Sensing
Heat blower OFF delay miniature slide switch set
Outputs
Spark
Gas Valve: GV
Inducer draft motor: IDM
Blower motor: FAN, COOL and HEAT speeds
Electric Air Cleaner: EAC
Humidier relay: HUM
Heat/Cool relay: H/C
LED indicators
Power, green LED: PWR
Status, green LED: OK
Flame status, yellow LED: FLAME
Low cost, form, fit and functional
replacement ignition control

Summary of content (1 pages)