Product Overview
ICM2901
INTERMITTENT PILOT GAS IGNITION CONTROL
LIS231
Low cost, direct replacement ignition control
Features
Specifications Wiring Diagram
Control Voltage: Line 24 VAC (18-30 VAC) 50/60 Hz
Anticipator Setting: 0.2A plus valve load @ 24 VAC
Prepurge: None
Trial for Ignition: 85 seconds
Flame Failure Response Time: 0.5 seconds
Retry: None
Operating Temperature:
• Minimum ambient temperature rating is -40°F
(-40°C)
• Maximum ambient rating when used with 2.0A
main valve is 160°F (71°C)
Relative Humidity: 0% to 95% non-condensing
• For use with intermittent pilot boilers,
furnaces and other heating appliances
• Microprocessor-based precision
• Monitors timing, trial for ignition, rollout
switch, flame sensing and lockout
• Remote flame sensing
• 100% lockout safety feature
• Compatible with LP or Natural Gas
• Replaces: Johnson Controls G770RJA-1,
York 025-27762-700 and comparable
ignition controls.
SENSE
GROUND
GROUND
GROUND
2
R1
1
3
4
M.V.
SPARK
P.V.
THS
Combination
Gas Valve
Flame Sensor
Spark
Electrode
Terminal numbers
shown on control label
1
1
M
M/P
P
Rollout
Switch
Thermostat
L1
(Hot)
High
Temperature
Limit
L2
(Neutral)
Burner Ground
R.O. SWH