Product Overview

ICM289
FURNACE CONTROL MODULE
LIS214-2
Specifications
Voltage Range: Line (98 to 132 VAC) @ 60 Hz
Cool Blower: 20A @ 120 VAC
Heat Blower: 20A @ 120 VAC
Inducer Motor: 5A @ 120 VAC
Cool Blower On Delay: 1 second
Cool Blower Off Delay: 1 second
Heat Blower On Delay: 45 seconds
Heat Blower Off Delay: 90, 150, 210, 270 seconds
Features
Low cost, form, fit and
functional replacement board
for Lennox
Controls inducer fan motor,
blower fan and monitors limit
switches
Microprocessor based design
Functions with all 24 VAC
thermostats
Replaces
Lennox: Replaces all BCC1, BCC2 and BCC3 circuit boards, including models LB-53622A,
BCC2-2REV8, 35K77, 35K7701, LB-90089A, 65K29, 65K2901, LB-50709BD, LB-65126A,
LB-89859, LB-87086A, LB-87086, LB-63622AA, LB-90676A, 40L8801, 30H6701, 48K98,
48K9801, 45K48, 45K4801, 78J61, 78J6101, 68H08.
Low cost, form, fit and functional
replacement ignition control

Summary of content (1 pages)