Product Overview
LIS242
ICM288
FURNACE CONTROL BOARD
Low cost, form, fit and functional replacement control board
Replaces
•
Rheem: 62-24084-82
Features
• Microprocessor-based precision
• Monitors pressure, roll-out and limit switches
• Controls gas valve, inducer draft motor, circulating blower and hot surface
ignitor.
• Reverse polarity detection
• Twinning compatible with another ICM288 board
• Diagnostic LEDs to aid in testing/troubleshooting
Specifications
•
Voltage Range: Line (98-132 VAC) @ 60Hz
•
Ignitor: 5A, 120 VAC
•
Cool Blower: 10A, 2HP, 240 VAC
•
Heat: 5A, ½ HP, 250 VAC
•
Inducer Blower: 4A, 120 VAC
•
Gas Valve: 1A, 24 VAC
•
Humidifier Motor: 0.5A, 24 VAC
•
Electronic Air Cleaner: 1A, 120 VAC