Product Overview

ICM2813
FURNACE CONTROL MODULE
LIS279
Specifications
Electrical
Electrical Rating @ 77°F (25°C)
Input Voltage: 18-30 VAC 50/60 Hz maximum
Igniter Current: 2.0 amp @ 80 VAC 50/60 Hz (resistive)
Inducer Relay: 2.2 FLA–3.5 LRA @ 120 VAC
Blower Relay: 14.5 FLA–25.0 LRA @ 120 VAC (2spd–H/C)
Gas Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf
Environmental
Operating Temp Range: -40° to 176°F (-40° to 80°C)
Humidity Range: 5 to 95% relative humidity
(non-condensing)
Replaces
Lennox: 10M9301, 12L6901, 32M8801, 56L8401, 24L8501, 63K8901, 97L4801, 100925-01, 100925-03, 17W9201, 23W5101,
30W2501, 69M0801, 69M1501, 83M00
White-Rodgers: 50A65-120, 50A65-121, 50A62-120, 50A62-121, 50A62-820, 21D83M-843, 50A66-122, 50A66-123
Features
• Controls the gas valve, inducer draft
motor, circulating blower and hot
surface ignitor
• Monitors system pressure and limit
switches
• Microprocessor based precision
• Diagnostic LEDs aid in testing and
trouble shooting
Conforms to UL STDs 60730-1 and 60730-2-5.
Certied to CSA STD E60730-1 and CSA STD
C22.2#60730-2-5
Manufactured in a state of the art vertically
integrated ISO9001:2015 facility
Quality Built to the Highest Standards
Form, t and functional design for wire to wire
replacement
Redundant Gas valve design conforms to ANSI Z21.20
Circuit board design incorporates double sided,
plated, through-hole construction for high reliability

Summary of content (1 pages)