Product Overview

ICM2811
FURNACE CONTROL MODULE
LIS276
Replaces
Goodman: PCBBF110/S, PCBBF123/S, 0130F00005/S, PCBBF112\S, B18099-26/S
White-Rodgers: 50A55-743, 50A55-289, 50T55-289
Features
• Controls the gas valve, inducer draft
motor, circulating blower and hot
surface ignitor
• Monitors system pressure and limit
switches
• Microprocessor based precision
• Twinning compatible with another
ICM2811 Control Board
• Diagnostic LEDs aid in testing and
troubleshooting
Specifications
Electrical
Electrical Rating @ 77°F (25°C)
Input Voltage: 18-30 VAC 50/60 Hz maximum
Igniter Current: 6.0 amp @ 120 VAC 50/60 Hz (resistive)
Inducer Relay: 2.2 FLA–3.5 LRA @ 120 VAC
Blower Relay: 14.5 FLA–25.0 LRA @ 120 VAC (2spd–H/C)
Gas Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf
Environmental
Operating Temp Range: -40° to 176°F (-40° to 80°C)
Humidity Range: 5 to 95% relative humidity
(non-condensing)
Conforms to UL STDs 60730-1 and 60730-2-5.
Certied to CSA STD E60730-1 and CSA STD
C22.2#60730-2-5
Manufactured in a state of the art vertically
integrated ISO9001:2015 facility
Quality Built to the Highest Standards
Form, t and functional design for wire to wire
replacement
Redundant Gas valve design conforms to ANSI Z21.20
Circuit board design incorporates double sided,
plated, through-hole construction for high reliability

Summary of content (1 pages)