Product Overview

LIS226-2
ICM2804
FURNACE CONTROL BOARD
Low cost, form, fit and functional replacement control board
Specifications
ENVIRONMENT
Ambient Temperature
Operating: -40ºF to 176ºF
Storage: -40ºF to 185ºF
Humidity: 5% to 95% R.H. (non-condensing) @ +55ºF
Vibration: 13.8Hz @ 0.2 Gs for one hour in each
orthogonal axis
ELECTRICAL
Voltage Range: Line (98-132 VAC) @ 60Hz
Cool Blower: 20A, 2 HP, 240 VAC
Heat: 10A, 240 VAC
Inducer Motor: 4A FLA, 8A LRA @ 120 VAC
TIMING
Inducer Pre-Purge Time: 1 second
Heat Blower On Delay: 45 seconds
Heat Blower Off Delays: 120 or 180 seconds
Cool Blower On Delay: 1 seconds
Cool Blower Off Delay: 1 seconds
Wiring Diagram
ALSF LL S
TR TH
NO
NC
NC
BRN
DSS
PRS
BRN
ORN
YEL
BLU
RED
RED
WHT
BLK
TRAN
BLK
BLU
RED
HGV
PILOT
GV
RED
BLK
WHT
JB
GRN
GRN
WHT
FU2
BLK
FUSE DISCONNECT
SWITCH
(WHEN REQUIRED)
1
2
PL2
BLK
WHT
BLK
WHT
2
1
PL3
BLK
BLK
IDM
Status
LED
C
4
1
2
3
MED LO
MED HI
HI
COM
LO
BLWM
PL4
BRN
BRN
CAP
Microprocessor-based
Controls vent motor and blower control
Monitors limit switch, pressure switch and gas valve
100% lockout safety feature
Compatible with LP or Natural Gas
Status LED for fault codes to aid in troubleshooting
Replaces: Carrier CES0110074-00 and CES0110074-01
Note: This board functions identically as the CES0110074-00
and the CES0110074-01. It is a form, fit and functional
replacement of the CES0110074-01. When replacing
the CES0110074-00 some quick connectors have to be
changed or added. EAC-1 and EAC-2 must have 1/4”
connectors. COM, SEC-1 and SEC-2 must have 3/16”
connectors.
Features

Summary of content (1 pages)