Product Overview

Application Assistance
800.365.5525
visit us at: www.icmcontrols.com
Phone
315.233.5266
Fax
315.233.5276
LIS163
ICM280
FURNACE CONTROL MODULE
All features and specications subject to change without notice.
Replaces
Goodman/Janitrol: B18099-06, B18099-08, B18099-10, B18099-13, B18099-13S
UTEC: 1012-933D
Texas Instruments: 41F-5
White-Rodgers: 50T35-730, 50T35-743
Features
Microprocessor based design for precise
timing
Functions with all 24 VAC thermostats
Drop-in replacement for Goodman, Janitrol,
Texas Instruments, White-Rodgers and
UTEC
Diagnostic fault codes (blinking LED) for
simple troubleshooting
Twinning compatible with another ICM280
For 80+ and 90+ applications
9-pin card slot connection and 9-pin Molex
connector on board
UL recognized
Specifications
Environment
Ambient temperature
– Operating: -40°C to 176°F
– Storage: -40°C to 185°C
Humidity: 5% to 95% R.H. (non-condensing) @ +55°C
Vibration: 13.8Hz @ 0.2 G’s for one hour in each
orthogonal axis
Flame spread: UL 94-VO rating
Electrical
Voltage range: Line (98 to 132 VAC) @ 60HZ
Ignitor: 5A @ 120 VAC
Cool blower: 10A, 2 HP, 240 VAC
Heat: 5A, HP, 240 VAC
Inducer motor: 4A, FLA-8.0 LRA @ 120 VAC
Gas valve: 1.5A @ 30 VAC
Timing
Trial for ignition: 7.0 seconds
– Ignition activation period: 5 seconds
– Flame establishing period: 2 seconds
Flame failure response time: 0.8 seconds maximum
Inducer pre-purge time: 1 second
Inducer post-purge time: 25 seconds 80% furnace
29 seconds 90% furnace
Ignitor warm up time:
– 15 seconds, 1
st
trial
– 20 seconds, 2
nd
and 3
rd
ignition trials
Total trials for ignition:
– 3 (automatically reset after 1 hour)
Heat blower on delay: 30 seconds
Heat blower off delays: 90, 120 and 150 seconds
Cool blower on delay: 5 seconds
Cool blower off delay: 60 seconds
Low cost, direct replacement furnace control board.