Spec Sheet

4.5" (114 mm)
20.8" (528 mm)
12.4" (315 mm)
5.25" (133 mm)
3" (8 mm)
1.6" (41 mm)
3.8" (97 mm)
2.6" (66 mm)
4.7" (119 mm)
9.9" (252 mm)9.9" (252 mm)
14.25" (362 mm)14.25" (362 mm)
C.
A.
D.
E.
B.
H.
F.
G.
3" (76 mm)
5.9" (150 mm)
2.3" (58 mm)2.3" (58 mm)
2.1" (53 mm)2.1" (53 mm)
5.25" (133 mm)5.25" (133 mm)
9.5" (241 mm)9.5" (241 mm)
3" (76 mm)3" (76 mm)
A.
C.
B.
Rear View Air Cooled
Rear View Water Cooled & Remote
Air In– Front
Air Out
21"
(533 mm)
24"
(610 mm)
27" (686 mm)
Rev: 04/16
Part: 7012
11100 E. 45th Avenue • Denver, CO 80239 • Phone: 1. 866. PURE. ICE • Fax: 303. 371. 6296 • www.iceomatic.com
Ice. Pure and Simple
MFI/FLAKEICEMAKER
MFI/FLAKEICEMAKER
Air Cooled
Please note: air-cooled units require 6" (152 mm) clearance
for air intake and exhaust.
A. Ice maker potable water in,
⁄"
F PT.
B.
Drain, " FPT.
C.
Hole for electricalconnection.
D.
Condenser inlet (water cooled only)
⁄" FPT.
E.
Condenser drain (water cooled only)
⁄" FPT.
F.
Liquid line, " male coupling for
precharged line set (remoteonly).
G.
Discharge line, " male coupling for
precharged line set (remoteonly).
H.
Remote condenser junction box
(remoteonly).
Specifications
Model Number Cond. Unit
Ice Production
per 24 hrs
Water Usage
gallons per 100 lbs of Ice
90°F air/70°F water
kWH Used
per 100 lbs of
ice @ 90°F air/
70°F water
Voltage
Characteristics
Min.
Circuit
Ampacity
Fuse
Size
Approx.
BTUs**
per hour
70°F air/
50°F water
lbs (kg)
90°F air/
70°F water
lbs (kg)
Potable Condenser
MFIA
Air 1,149 (521)) 885 (401)
12.0
- 3.60
208-230/60/1
11.8
15
9000
MFIW Water 1,137 (516) 959 (435) 70 2.70 11.2
MFIR
Remote* 1,054 (478) 950 (431) - 3.65 15.3 20
MFIA Air 1,260 (572) 900 (408) - 3.25
220-240/50/1
13.4 20
MFIW Water 1,230 (558) 1,000 (454) 75 2.60 13.1 15
Dimensions
NOTES:
Number of Wires: 3 (including ground)
Approx. Shipping Weight lbs (kg): MFIA 215 (98) • MFIW 230 (104) • MFIA 215 (98) • MFIW 210 (95) • MFIR 230 (104)
Refrigerant Type: RA
ENERGY STAR qualified machine. Please see our website www.iceomatic.com for the latest list of ENERGY STAR qualified machines and available rebates
*Requires GRC  Condenser.
**BTUH is calculated to ˚ F Evaporator, ˚F Condensing, and  PSIG. Value is estimated.
ALLMODELS
W x D x H (in.)
21 x 24 x 27
W x D x H (mm)
533 x 610 x 686
Operating Requirements
MAXIMUM
60 Hz 50Hz
AmbientTemp. Range Air 50˚F (10˚C)
100˚F (38˚C)
110˚F (43˚C)
WaterTemp. 40˚F (4.4˚C) 90˚F (32˚C)
Water Pressure 20 PSIG (1.4 BAR) 120 PSIG (8.3 BAR)
MINIMUM