Specification Sheet
Rev: 06/10
Part: 7011
11100 E. 45th Avenue • Denver, CO 80239 • Phone: 1. 866. PURE. ICE • Fax: 303. 371. 6296 • www.iceomatic.com
Ice. Pure and Simple
MFI",""/"," #)FLAKE)ICE)MAKER
Air Cooled
Please note: air-cooled units require 6" (152 mm) clearance for air
intake and exhaust. Please note: air-cooled units require 6"
(152 mm) clearance for air intake and exhaust.
A. Ice maker potable water in, 3⁄8" FPT.
B. Drain, 3⁄4" FPT.
C. Hole for electricalconnection.
D. Condenser inlet (water cooled only)
3⁄8" FPT.
E. Condenser drain (water cooled only)
1⁄2" FPT.
F. Liquid line, 3⁄8" male coupling for
precharged line set (remoteonly).
G. Discharge line, 1⁄2" male coupling for
precharged line set (remoteonly).
H. Remote condenser junction
box (remoteonly).
ALL*MODELS
Dimensions
W x D x H (in.) 21 x 24 x 27
W x D x H (mm) 533 x 610 x 686
NOTES:
Number of Wires: 3 (including ground)
Approx. Shipping Weight lbs (kg): MFI",""A 205 (93) • MFI",""W 200 (91 kg) • MFI",""R 220 (100 kg) • MFI","#A 205 (93 kg) • MFI","#W 200 (91 kg)
Refrigerant Type: R'"'A
Operating Requirements
Specifications
Model Number Cond. Unit
Ice Production
per 24 hrs
Water Usage
gallons per 100 lbs of Ice
90°F air/70°F water
kWH Used
per 100 lbs of
ice @ 90°F air/
70°F water
Voltage
Characteristics
Min.
Circuit
Ampacity
Fuse
Size
Approx.
BTUs**
per hour
70°F air/
50°F water
lbs (kg)
90°F air/
70°F water
lbs (kg)
Potable Condenser
MFI",""A Air 768 (348) 579 (263) 12.0 (45.4) - 4.8
115/60/1
21.0
30
7, 400
MFI",""W Water 859 (390) 690 (313) 12.0 (45.4) 86.5 (327.3) 4.9 19.5 4,400
MFI,""R Remote* 819 (371) 675 (306) 12.0 (45.4) - 4.3 23.5 5,600
MFI","#A Air 756 (343) 571 (259) 12.0 (45.4) - 4.2 230/50/1 10.1
15
7, 400
MFI","#W Water 737 (334) 604 (274) 12.0 (45.4) 88.7 (335.7) 3.6 230/50/1 9.5 4,400
MFI%)%%/%)%#*-*FLAKE*ICE*MAKER
MAXIMUM
60 Hz 50Hz
AmbientTemp. Range Air
50˚F (10˚C)
100˚F (38˚C)
110˚F (43˚C)
WaterTemp.
40˚F (4.4˚C) 90˚F (32˚C)
Water Pressure
20 PSIG (1.4 BAR) 120 PSIG (8.3 BAR)
MINIMUM
*Requires GRC!"##" Remote Condenser **BTUH is calculated to #˚F Evaporator, "##˚F Condensing, and $$ PSIG.
Air, Water Cooled & Remote
4.5" (114 mm)
20.8" (528 mm)
12.4" (315 mm)
5.25" (133 mm)
3" (8 mm)
1.6" (41 mm)
3.8" (97 mm)
2.6" (66 mm)
4.7" (119 mm)
9.9" (252 mm)9.9" (252 mm)
14.25" (362 mm)14.25" (362 mm)
C.
A.
D.
E.
B.
H.
F.
G.
3" (76 mm)
5.9" (150 mm)
Air In– Front
Air Out
21"
(533 mm)
24"
(610mm)
27" (686 mm)