Specification Sheet
Model Number Cond. Unit
Ice Production
per 24hrs
Water Usage
gallons per 100 lbs of Ice
90°F air/70°F water
kWH Used
per 100 lbs of
ice @ 90°F air/
70°F water
Voltage
Characteristics
Min.
Circuit
Ampacity
Fuse
Size
Approx.
BTUs
per hour
50°F air/
50°F water
lbs (kg)
70°F air/
50°F water
lbs (kg)
90°F air/
70°F water
lbs (kg)
Potable Condenser
GEMDA
Air
309 (140) 274 (124) 210 (95)
24 (91) -
33 115/60/1
6.0 10 161 (73)
GEMDA
265 (120) 251 (114) 190 (86) 29.5 230/50/1
Rev: 11/20
11100 E. 45th Avenue • Denver, CO 80239 • Phone: 1. 866. PURE. ICE • Fax: 303. 371. 6296 • www.iceomatic.com
Ice. Pure and Simple
GEMDA/APEARLICE
®
/WATERDISPENSER
NOTES:
• 1 lb. apx. = 32 fl. oz.
• Vends per hour are based on 70˚F Air/50˚F Water
• It is possible to change the "Ice-Only" default seing to a different default seing by pushing the corresponding buon for 5 seconds (factory default if "Ice-Only").
• Cordset included
ALLMODELS
Dimensions
W x D x H (in.)
15.5 x 25.5 x 34.5
W x D x H (mm)
390 x 645 x 877
Specifications
Number of Vends (Servings) Per Hour From Full Bin + Recovery = Total Vends
Model
Number
Bin
Storage
lbs/kg
1 Hour
Recovery
Cap. lbs/kg
2 fl. oz
Bin
2 fl. oz.
Recovery
To t a l
2 fl. oz.
Vends
4 fl. oz.
Bin
4 fl. oz
Recovery
To t a l
4 fl. oz.
Vends
6 fl. oz.
Bin
6fl. oz.
Recovery
To t a l
6fl. oz.
Vends
8 fl. oz.
Bin
8 fl. oz.
Recovery
To t a l
8 fl. oz.
Vends
GEMDA
12/5.5 11.4/5.2 192 + 182 = 374 96 + 97 = 187 64 + 61 = 125 48 + 46 = 94
GEMDA
PEARLICE®ICE/WATERDISPENSER
GEMDA/A
Item #:
Project:
Quantity:
Milano Madrid Chicago Dubai Singapore Shanghai Johannesburg
24 h ice production kg
°C Amb. / °C Water
Energy
consumption (*)
Water
usage (*)
Instant
power
Compressor Circuit wires
Max. fuse
size
Version Voltage
10°C/10°C 21°C/10°C 32°C/21°C
kWh/
100 kg
kWh/
24h
l/h W W No. x Ømm
2
A
kg kg kg
TC L 180 AS 230/50/1 120 114 86 13.4 11.5 4.2 500
1300 3 x 1.5 10
TC S 180 AS 230/50/1 120 114 86 13.4 11.5 4.2 500
1300 3 x 1.5 10
TC L 180 ASM 230/50/1 120 114 86 13.4 11.5 4.2 500
1300 3 x 1.5 10
TC S 180 ASM 230/50/1 120 114 86 13.4 11.5 4.2 500
1300 3 x 1.5 10
TC S 180 EVO 230/50/1 120 114 86 13.4 11.5 4.2 500
1300 3 x 1.5 10
TC S 180 AS 115/60/1 140 124 95 15.0 13.8 4.5 600
1370 3 x 1.5 10
TC L 180 AS 230/60/1 120 114 86 16.8 14.5 4.0 670
1400 3 x 1.5 10
TC S 180 AS 230/60/1 120 114 86 16.8 14.5 4.0 670
1400 3 x 1.5 10
TC L 180 ASM 230/60/1 120 114 86 16.8 14.5 4.0 670
1400 3 x 1.5 10
TC S 180 ASM 230/60/1 120 114 86 16.8 14.5 4.0 670
1400 3 x 1.5 10
(*) Data refer to 32°C Amb. / 21°C Water temperature conditions
Ice Machine/Dispenser 120 kg
Ice Machine/Dispenser 120 kg
UNIT OF MEASUREMENT: mm
1. 25/32” WATER OUTLET
2. 3/4” GAS - WATER INLET
3. CORD SET
4. BASE OPENING FOR
HIDDEN CONNECTIONS
UNIT DATA SHIPPING DATA
Size (W x D x H)
390 x 663 x 874 mm
Carton (W x D x H)
460 x 730 x 1040 mm
Net weight
64 kg
Weight
73 kg
TCL 180 LONG TCS 180 SHORT
All data refer to R404A refrigerant models
TC 180
Operating Requirements
MAXIMUM
60 Hz
AmbientTemp. Range Air
50˚F (10˚C)
100˚F (38˚C)
WaterTemp.
40˚F (4.4˚C)
Water Pressure
14 PSIG (1 BAR) 70 PSIG (5 BAR)
Electrical Voltage
-10% +10%
MINIMUM
AIR EXHAUST
12"
25.5"
34"
2.25"
.5"
15.5" 5"
15.5"
11"
4.4"
1.6"
7.7"
1.4"
1.2"