Service Manual
ELEVATION SERIES CIM CUBER HIGH AND LOW FLOAT SWITCHES AND HOUSING
37
The Bridge Thickness on units under 400# production should be 3/16” while units over 400# pro-
duction should be 1/8” thick when measured across the middle of the plate. Minor Adjustments
can be made to the bridge thickness by moving the Water Level Adjustment Arm of the Float
Housing up for a thinner bridge or down for a thicker bridge. This adjustment can be made at
any time during the freeze or defrost cycle and the results verified on the following cycle.