Service Manual

ELEVATION SERIES CIM CUBERS SEQUENCE OF OPERATIONS
20
CONTROL BOARD - HARVEST
After the Water Inlet Valve closes following the 20 second time out, the Hot Gas Valve and Harvest Assist
will remain energized until the ice slab is harvested from the Evaporator. At this point the unit is reading
the Curtain Switch (s) and/or Bin Thermostat (if added).
BROWN
BLUE
VIOLET
BLACK
RED
TAN
PINK
YELLOW
= Illuminated LED
WHITE
WHITE
BLUE w/ WHITE
BLUE w/ RED
BLUE
12V DC Switches
Line Voltage
Components
R1 R2 R3 R4 R5 R6