ELEVATION SERIES CIM CUBERS SEQUENCE OF OPERATIONS
10
CONTROL BOARD - FREEZE CYCLE
A quick press of the POWER button on the Push Pad or Board will start the Freeze cycle. The Water Inlet
Valve will be energized (R4 LED on Board illuminated) and water will begin flowing into the Sump. As the
water rises, the contacts in the Low Water Float will open (Switch LED off). The Water Inlet Valve will
remain energized until the High Water Float contacts open (Switch LED off). The Water inlet Valve will be
de-energized (R4 LED on Board off).
Note: Minimum Freeze Cycle - 5 minutes (from Compressor Start.)
Maximum Freeze Cycle - 1 hour.